Skip to main content
QUICK REVIEW

[Paper Review] The QC Relaxation: Theoretical and Computational Results on Optimal Power Flow

Carleton Coffrin, Hassan Hijazi|arXiv (Cornell University)|Feb 27, 2015
Optimal Power Flow DistributionEngineering31 references27 citations
TL;DR

This paper introduces the Quadratic Convex (QC) relaxation for AC Optimal Power Flow, which strengthens the Second-Order Cone (SOC) relaxation by preserving tighter voltage variable relationships through convex envelopes of the polar power flow equations. It demonstrates theoretically that QC is stronger than SOC and neither dominates nor is dominated by the SDP relaxation, while computationally showing QC achieves significantly better feasibility and accuracy—especially under tight phase angle bounds—without sacrificing efficiency compared to SDP.

ABSTRACT

Convex relaxations of the power flow equations and, in particular, the Semi-Definite Programming (SDP) and Second-Order Cone (SOC) relaxations, have attracted significant interest in recent years. The Quadratic Convex (QC) relaxation is a departure from these relaxations in the sense that it imposes constraints to preserve stronger links between the voltage variables through convex envelopes of the polar representation. This paper is a systematic study of the QC relaxation for AC Optimal Power Flow with realistic side constraints. The main theoretical result shows that the QC relaxation is stronger than the SOC relaxation and neither dominates nor is dominated by the SDP relaxation. In addition, comprehensive computational results show that the QC relaxation may produce significant improvements in accuracy over the SOC relaxation at a reasonable computational cost, especially for networks with tight bounds on phase angle differences. The QC and SOC relaxations are also shown to be significantly faster and reliable compared to the SDP relaxation given the current state of the respective solvers.

Motivation & Objective

  • To analyze the theoretical and computational properties of the Quadratic Convex (QC) relaxation for AC Optimal Power Flow.
  • To compare QC with established relaxations—SDP and SOC—on theoretical strength and computational performance.
  • To evaluate the impact of tight phase angle difference bounds on relaxation quality and feasibility.
  • To assess the reliability, speed, and optimality gap performance of QC, SOC, and SDP relaxations on realistic test cases with shunts, charging, and transformers.
  • To explore the potential of QC relaxation in practical power system applications such as unit commitment and transmission expansion planning.

Proposed method

  • The QC relaxation is derived by applying convex envelopes to the polar representation of the AC power flow equations, preserving stronger voltage variable dependencies.
  • The method formulates the AC-OPF problem using complex power, voltage, current, and admittance, with constraints based on Kirchhoff’s Current Law, Ohm’s Law, and power definitions.
  • The QC relaxation is reformulated using second-order cone constraints to enable efficient solution with modern mixed-integer quadratic programming solvers.
  • Theoretical analysis compares QC to SOC and SDP relaxations using equivalence of second-order cone constraints and power flow equations.
  • Computational evaluation uses 93 NESTA test cases with realistic side constraints, including shunt admittances, line charging, and transformers.
  • The study employs standard solvers (e.g., Gurobi, CPLEX) and compares solution quality, optimality gaps, runtime, and numerical reliability across all three relaxations.

Experimental results

Research questions

  • RQ1How does the QC relaxation compare in strength to the SOC and SDP relaxations in terms of theoretical relaxation bounds?
  • RQ2Does the QC relaxation improve feasibility and optimality gap compared to SOC, especially under tight phase angle difference constraints?
  • RQ3Is the QC relaxation computationally more efficient and reliable than the SDP relaxation given current solver capabilities?
  • RQ4Can the QC relaxation achieve feasible AC power flow solutions where SDP and SOC fail or produce large gaps?
  • RQ5What is the trade-off between solution accuracy and computational cost when using QC versus SOC or SDP relaxations?

Key findings

  • The QC relaxation is theoretically stronger than the SOC relaxation, as it preserves tighter links between voltage variables through convex envelopes of the polar power flow equations.
  • The QC relaxation neither dominates nor is dominated by the SDP relaxation, indicating a non-comparable relationship in terms of solution strength.
  • On 53 challenging NESTA test cases, QC achieved feasible AC power flow solutions in 5 cases where SDP also succeeded, and outperformed SDP in optimality gap on several cases with tight phase angle bounds.
  • For cases with tight phase angle difference limits (e.g., SAD cases), QC reduced optimality gaps significantly compared to SOC, demonstrating superior accuracy.
  • The QC relaxation was 2–5 times slower than SOC but remained significantly faster and more reliable than SDP, which failed to converge on 8 cases, reported numerical warnings on 4, and ran out of memory on 3 high-node-count systems.
  • In all cases where SDP found a feasible solution, the AC heuristic found a solution of equal quality in a fraction of the time, highlighting the practical inefficiency of SDP despite its theoretical strength.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.