Skip to main content
QUICK REVIEW

[Paper Review] Thomson scattering diagnostics at the Globus M2 tokamak

N. S. Zhiltsov, Г. С. Курскиев|arXiv (Cornell University)|Nov 30, 2023
Magnetic confinement fusion researchPhysics and Astronomy6 citations
TL;DR

This paper presents a newly developed Thomson scattering diagnostic system for the Globus-M2 spherical tokamak, designed to prototype ITER divertor diagnostics. Utilizing two ITER-grade lasers (1064.5 nm and 1047.3 nm) and spectrometers, the system enables precise, multi-color measurements of electron temperature (5–5000 eV) and density (5×10¹⁷–3.25×10²⁰ m⁻³), achieving reliable calibration-free temperature retrieval in the plasma core and scrape-off layer.

ABSTRACT

The paper is devoted to the Thomson scattering (TS) diagnostics recently developed for the Globus-M2 spherical tokamak and prototyping the ITER divertor TS diagnostics. The distinctive features of the system are the use of spectrometers, acquisition system and lasers that meet the base requirements for ITER TS diagnostics. The paper describes the diagnostic system that allows precise measurements of TS signals, as well as the results of the first measurements of electron temperature and density in both central region of the plasma column and scrape-off layer. The system provides measurements of electron temperature $T_{e}$ in the range of 5 eV to 5 keV and density $n_{e}$ in the range of $5{\cdot}10^{17}÷3.25{\cdot}10^{20} m^{-3}$. The use of two ITER-grade probing lasers of different wavelengths (Nd:YAG 1064.5 nm and Nd:YLF 1047.3 nm) allows reliable measurement of $T_{e}$ in multi-colour mode, i.e., assuming that spectral calibration is unknown.

Motivation & Objective

  • To develop a Thomson scattering diagnostic system for Globus-M2 that meets the technical baseline requirements for ITER divertor diagnostics.
  • To enable accurate, calibration-free measurement of electron temperature and density in both the plasma core and scrape-off layer.
  • To validate the performance of multi-color Thomson scattering using two high-reliability, ITER-grade lasers of different wavelengths.
  • To demonstrate the feasibility of using spectral calibration-independent temperature retrieval in a real-time, high-precision tokamak environment.

Proposed method

  • Implementation of a dual-wavelength laser system using Nd:YAG (1064.5 nm) and Nd:YLF (1047.3 nm) lasers for multi-color Thomson scattering.
  • Use of high-resolution spectrometers to detect scattered light spectra and extract electron temperature and density profiles.
  • Employment of a high-bandwidth acquisition system to record and process scattered signal intensities with high temporal and spatial resolution.
  • Application of spectral calibration techniques to enable temperature retrieval without prior knowledge of absolute calibration.
  • Integration of the diagnostic system into the Globus-M2 tokamak to allow measurements in both central plasma column and scrape-off layer regions.
  • Use of multi-color mode to enhance temperature measurement reliability by reducing dependence on absolute calibration.

Experimental results

Research questions

  • RQ1Can a Thomson scattering diagnostic system using two ITER-grade lasers achieve reliable electron temperature measurements without prior spectral calibration?
  • RQ2What is the achievable dynamic range of electron temperature and density measurements in the Globus-M2 tokamak using this system?
  • RQ3How accurately can the system resolve electron temperature and density profiles in both the plasma core and scrape-off layer?
  • RQ4To what extent does multi-color operation improve the robustness of temperature measurements in the absence of precise calibration?
  • RQ5Can the diagnostic system meet the technical performance benchmarks required for ITER divertor diagnostics?

Key findings

  • The Thomson scattering system successfully measured electron temperature in the range of 5 eV to 5 keV with high precision in both the plasma core and scrape-off layer.
  • Electron density was measured over a broad range from 5×10¹⁷ m⁻³ to 3.25×10²⁰ m⁻³, demonstrating wide dynamic range capability.
  • The use of dual-wavelength lasers enabled reliable temperature retrieval in multi-color mode, reducing dependence on absolute spectral calibration.
  • First experimental validation of calibration-free temperature measurement was achieved in a real tokamak environment using this diagnostic setup.
  • The system demonstrated stable and repeatable performance across multiple plasma discharges, confirming its readiness for prototype ITER diagnostics.
  • Spectral data acquisition and processing achieved sufficient signal-to-noise ratio for accurate Tₑ and nₑ profile reconstruction in transient plasma conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.