Jiandong Zhang, Zijing Zhang|Figshare|Jun 20, 2018
Orbital Angular Momentum in OpticsPhysics and Astronomy24 references11 citations
TL;DR

This paper proposes a hybrid SU(1,1)-SU(2) interferometer using orbital angular momentum (OAM) coherent states to achieve super-sensitive angular displacement estimation. By combining optical parametric amplification with balanced homodyne detection, the protocol attains sub-shot-noise-limited sensitivity, saturating the quantum Cramér-Rao bound under ideal conditions and demonstrating robustness against photon loss exceeding 30%.

ABSTRACT

In this paper, we propose a protocol for angular displacement estimation based upon orbital angular momentum coherent state and a SU(1,1)-SU(2) hybrid interferometer. This interferometer consists of an optical parametric amplifier, a beam splitter and reflection mirrors, hereon we use a quantum detection strategy $\---$ balanced homodyne detection. The results indicate that super-resolution and super-sensitivity can be realized with ideal condition. Additionally, we study the impact of photon loss on the resolution and the sensitivity, and the robustness of our protocol is also discussed. Finally, we demonstrate the advantage of our protocol over SU(1,1) and summarize the merits of orbital angular momentum-enhanced protocol.

Motivation & Objective

  • To develop a quantum metrology protocol for angular displacement estimation that surpasses classical limits.
  • To leverage the infinite-dimensional Hilbert space of orbital angular momentum (OAM) for enhanced sensitivity compared to spin angular momentum.
  • To integrate SU(1,1) interferometry's gain in sensitivity with SU(2) interferometry's practicality using coherent states.
  • To analyze the impact of photon loss on resolution and sensitivity, evaluating robustness in realistic conditions.
  • To demonstrate superiority over standard SU(1,1) and non-OAM protocols in sensitivity scaling.

Proposed method

  • Employ a hybrid interferometer architecture combining an optical parametric amplifier (OPA), beam splitter (BS), and reflection mirrors to replace traditional beam splitters in SU(2) or OPA in SU(1,1) interferometers.
  • Use spiral phase plates (SPPs) to imprint OAM on the input coherent state, enabling mode-dependent phase shifts proportional to the OAM quantum number ℓ.
  • Introduce angular displacement via Dove prisms (DPs) that induce a phase difference of 2ℓφ between OAM modes.
  • Apply balanced homodyne detection to the output ports to extract phase information with high precision.
  • Model the system using transformation matrices in phase space for OPA, angular displacement, and beam splitter processes.
  • Derive the mean photon number as N = cosh(2g)|α|² + 2 sinh²g, where g is the OPA squeezing parameter and |α|² is the input coherent state intensity.

Experimental results

Research questions

  • RQ1Can OAM-enhanced coherent states in a hybrid SU(1,1)-SU(2) interferometer achieve sub-shot-noise-limited sensitivity for angular displacement estimation?
  • RQ2How does photon loss affect the resolution and sensitivity of the proposed protocol compared to ideal conditions?
  • RQ3What is the scaling advantage of OAM in enhancing sensitivity relative to non-OAM protocols?
  • RQ4Does the protocol achieve the quantum Cramér-Rao bound (QCRB) under ideal conditions?
  • RQ5How does the sensitivity of this protocol compare to that of standard SU(1,1) interferometers?

Key findings

  • Under ideal conditions, the protocol achieves both super-resolution and super-sensitivity, with 100% visibility in the output signal.
  • The minimum uncertainty in angular displacement estimation, Δφ_min, saturates the quantum Cramér-Rao bound (QCRB) when |α|² ≫ 1 and sinh²g ≫ 1.
  • The protocol demonstrates robustness against photon loss, maintaining 100% visibility and resisting loss rates above 30%.
  • The sensitivity of the proposed protocol improves by a factor of √2 compared to standard SU(1,1) interferometers.
  • OAM enhancement provides a sensitivity boost by a factor of 2√2ℓ compared to non-OAM protocols, scaling linearly with the OAM quantum number ℓ.
  • The resolution is limited to 1/(2ℓ) in practical detection due to the OAM-dependent phase shift, constraining the scanning range.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.