[Paper Review] Towards Self-Calibrating Inertial Body Motion Capture
This paper proposes an online, sliding-window constrained weighted least squares method for simultaneous self-calibration of inertial sensor-to-segment (I2S) parameters and human body motion estimation using inertial measurement units (IMUs). By integrating motion, measurement, and biomechanical models with novel stochastic priors based on kinematics, anatomy, and parameter regularization, the method achieves accurate and repeatable I2S calibration without relying on magnetometers or predefined calibration poses, converging to sub-degree orientation and centimeter-level position accuracy even from highly inaccurate initializations.
This paper presents a novel online capable method for simultaneous estimation of human motion in terms of segment orientations and positions along with sensor-to-segment calibration parameters from inertial sensors attached to the body. In order to solve this ill-posed estimation problem, state-of-the-art motion, measurement and biomechanical models are combined with new stochastic equations and priors. These are based on the kinematics of multi-body systems, anatomical and body shape information, as well as, parameter properties for regularisation. This leads to a constrained weighted least squares problem that is solved in a sliding window fashion. Magnetometer information is currently only used for initialisation, while the estimation itself works without magnetometers. The method was tested on simulated, as well as, on real data, captured from a lower body configuration.
Motivation & Objective
- To address the lack of robust, practical calibration methods in inertial body motion capture that do not require precise user-executed calibration poses.
- To develop an online-capable method that simultaneously estimates human motion and I2S calibration parameters from inertial sensor data.
- To reduce dependency on magnetometers by enabling calibration without their use during estimation.
- To improve system usability for non-expert users by eliminating the need for trained operators or rigid calibration protocols.
- To ensure convergence to consistent, repeatable calibration results from highly inaccurate initializations.
Proposed method
- Uses a sliding window approach to solve a constrained weighted least squares (WLS) optimization problem in real time, enabling online processing.
- Combines state-of-the-art motion, measurement, and biomechanical models with novel stochastic equations and priors based on kinematics and anatomical constraints.
- Incorporates priors for sensor-to-segment position and orientation that regularize the ill-posed estimation problem.
- Employs a shape prior based on body geometry to improve calibration stability and convergence.
- Initializes with magnetometer data but performs estimation without relying on it, enhancing robustness in dynamic environments.
- Applies a moving horizon strategy to avoid processing delay in streamed data.
Experimental results
Research questions
- RQ1Can a self-calibrating inertial mocap system reliably estimate I2S parameters and body motion from arbitrary initializations without requiring predefined calibration poses?
- RQ2To what extent can the method reduce dependency on magnetometers while maintaining calibration accuracy?
- RQ3How well does the method converge to consistent calibration results from highly inaccurate initial I2S estimates?
- RQ4What is the impact of biomechanical and anatomical priors on the stability and accuracy of the calibration process?
- RQ5Can the method achieve repeatable and accurate calibration across different subjects and motion types in real-world settings?
Key findings
- For simulated data, the method achieved sub-degree orientation accuracy and centimeter-level position accuracy, with convergence observed even from initial angular offsets up to 131.19°.
- In real data experiments, initial I2S orientation errors of up to 113.6° converged to final differences of less than 8.5° from reference values.
- The maximum in-between difference among final I2S calibrations across all sensors was only 1.7°, indicating high repeatability.
- The method successfully reduced initial position errors from up to 0.092 m to within 0.067 m, with the most accurate results for upper limbs.
- The algorithm maintained consistent performance across different initializations, including a perfect one, confirming robustness to initialization variance.
- The shape prior did not introduce bias, as identical results were obtained with and without it, confirming its role in regularization rather than biasing.