[Paper Review] UncertaINR: Uncertainty Quantification of End-to-End Implicit Neural Representations for Computed Tomography
This paper proposes UncertaINR, a Bayesian framework for uncertainty quantification (UQ) in implicit neural representations (INRs) for computed tomography (CT) reconstruction. By applying Monte Carlo dropout and other Bayesian deep learning methods to INRs, UncertaINR achieves well-calibrated uncertainty estimates while maintaining reconstruction accuracy competitive with state-of-the-art methods—surprisingly outperforming more complex approaches like Hamiltonian Monte Carlo and deep ensembles in both calibration and efficiency.
Implicit neural representations (INRs) have achieved impressive results for scene reconstruction and computer graphics, where their performance has primarily been assessed on reconstruction accuracy. As INRs make their way into other domains, where model predictions inform high-stakes decision-making, uncertainty quantification of INR inference is becoming critical. To that end, we study a Bayesian reformulation of INRs, UncertaINR, in the context of computed tomography, and evaluate several Bayesian deep learning implementations in terms of accuracy and calibration. We find that they achieve well-calibrated uncertainty, while retaining accuracy competitive with other classical, INR-based, and CNN-based reconstruction techniques. Contrary to common intuition in the Bayesian deep learning literature, we find that INRs obtain the best calibration with computationally efficient Monte Carlo dropout, outperforming Hamiltonian Monte Carlo and deep ensembles. Moreover, in contrast to the best-performing prior approaches, UncertaINR does not require a large training dataset, but only a handful of validation images.
Motivation & Objective
- To address the critical need for uncertainty quantification (UQ) in medical imaging, particularly in CT, where model errors can lead to misdiagnosis.
- To evaluate Bayesian deep learning methods for UQ in implicit neural representations (INRs), which are increasingly used in low-data, high-stakes medical imaging.
- To determine whether computationally efficient methods like Monte Carlo dropout can achieve better calibration than expensive alternatives such as Hamiltonian Monte Carlo or deep ensembles in INR-based CT reconstruction.
- To demonstrate that INRs can achieve high-quality UQ without requiring large training datasets, relying instead on only a few validation images.
Proposed method
- Proposes a Bayesian reformulation of INRs, named UncertaINR, for uncertainty-aware CT image reconstruction.
- Applies multiple Bayesian deep learning inference techniques: Bayes-by-Backprop, Monte Carlo Dropout (MCD), Deep Ensembles (DE), and Hamiltonian Monte Carlo (HMC).
- Uses a probabilistic model where the INR parameterizes a continuous function $ f:(x,y) \to [0,1] $, with uncertainty quantified via posterior sampling.
- Employs a negative log-likelihood (NLL) loss and total variation (TV) regularization to stabilize training and improve reconstruction quality.
- Evaluates UQ performance using metrics like Expected Calibration Error (ECE) and Negative Log-Likelihood (NLL), alongside reconstruction accuracy (SNR).
- Introduces a cold-posterior effect analysis in the context of HMC sampling, showing that tempering improves SNR but degrades uncertainty calibration.
Experimental results
Research questions
- RQ1Can Bayesian deep learning methods provide well-calibrated uncertainty estimates in implicit neural representations for CT reconstruction?
- RQ2Does Monte Carlo Dropout outperform more computationally intensive methods like Hamiltonian Monte Carlo and deep ensembles in UQ for INRs?
- RQ3Can UncertaINR achieve high reconstruction accuracy and reliable uncertainty quantification with minimal training data?
- RQ4What causes the cold-posterior effect in INR-based CT reconstruction, and how does it affect both uncertainty and reconstruction performance?
Key findings
- Monte Carlo Dropout (MCD) achieves the best uncertainty calibration among all evaluated Bayesian methods, outperforming Hamiltonian Monte Carlo and deep ensembles in the INR setting.
- MCD maintains competitive reconstruction accuracy, achieving SNR values of $ 3.44 \pm 0.11 $ (DE-5 MCD UINR) and $ 3.42 \pm 0.10 $ (DE-10 MCD UINR) on the AAPM test set.
- HMC-based methods achieve high SNR ($ 3.06 \pm 0.09 $) but suffer from poor calibration, with ECE values of $ -0.033 \pm 0.010 $, indicating overconfidence.
- The cold-posterior effect is observed in HMC-GOP-TV, where lowering the temperature improves SNR but degrades both ECE and NLL, suggesting a trade-off between accuracy and uncertainty reliability.
- Deep ensembles with MCD (e.g., DE-5 MCD UINR) further improve performance, achieving NLL of $ -5.76 \pm 0.80 $, indicating strong joint accuracy and calibration.
- UncertaINR achieves well-calibrated uncertainty without requiring large training datasets, relying only on a few validation images, which is a significant advantage in data-scarce medical imaging.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.