[Paper Review] Unifying Viscocapillary and Inertial Regimes in Selective Withdrawal
The paper proposes a regime-spanning master curve for entrainment in selective withdrawal that unifies viscocapillary and inertial limits using a Moody-diagram–like normalization, applicable to Newtonian and generalized-Newtonian lower layers.
Selective withdrawal extracts only a single phase from a stratified multi-layer system. Entrainment occurs when a critical condition draws up the static layer which is not being withdrawn. Existing studies provide robust scalings within distinct limiting regimes. These include viscocapillary-dominated entrainment at low Reynolds number. They also include inertia-dominated entrainment at high Reynolds number. However, a single unifying representation remains to be explored in the literature. This limitation is most evident in transitional conditions between classical limits. It is also pronounced when the lower layer is non-Newtonian. Here we report selective-withdrawal experiments spanning these conditions. The upper layer is Newtonian, using PDMS or soybean oil. The lower layer is either Newtonian water or shear-thinning xanthan-gum solutions. We propose a unified framework that connects these previously separated regimes. The framework adopts a ``Moody diagram'' type representation for selective withdrawal. We collapse normalized critical submergence height using a Reynolds-like control parameter. Surface-tension effects enter subdominantly through the capillary length. The resulting master curve captures the transition between dominant balances. It connects viscous and shear-controlled entrainment to inertial entrainment. The collapse also clarifies how shear thinning enters the organization. Shear thinning primarily renormalizes the viscous correction through an effective viscosity. It does not alter the inertial baseline scale that anchors the normalization. This regime-spanning representation avoids regime-by-regime correlation switching. It provides a compact diagnostic for entrainment thresholds across fluid types. The diagnostic applies to Newtonian and generalized-Newtonian two-layer systems.
Motivation & Objective
- Motivate a regime-spanning representation for selective withdrawal that remains interpretable across transitional conditions between classical viscocapillary and inertial limits.
- Introduce a Moody-diagram–style master curve that collapses entrainment onset data using an inertial baseline with viscous corrections.
- Incorporate non-Newtonian (shear-thinning) effects via an effective viscosity and show how they renormalize viscous corrections without altering the inertial baseline.
Proposed method
- Formulate an interfacial normal-stress balance to derive governing stress scales.
- Define a Reynolds-like control parameter Re_Ls based on a composite scale L_s = max(l_c, a) and a vertical inertial scale S_I ∼ (Q^2/g)^(1/5).
- Normalize the critical submergence S_c by the inertial scale S_I to obtain Y = S_c g^(1/5) / Q^(2/5).
- Propose a master curve Y = A + B Re_Ls^(-1/3) that interpolates between inertial plateau and viscous/shear-dominated corrections.
- Account for shear-thinning by evaluating an effective viscosity η_L,eff at a characteristic interfacial shear rate and show it renormalizes the viscous correction rather than the inertial baseline.
Experimental results
Research questions
- RQ1Can a single, regime-spanning framework unify entrainment onset across viscocapillary and inertial regimes for two-layer fluids?
- RQ2How do capillary, viscous, inertial, and gravitational effects combine in a unified diagnostic for entrainment thresholds?
- RQ3Do shear-thinning lower layers collapse onto the same master curve when viscosity is evaluated at an appropriate shear-rate scale?
Key findings
- A Moody-diagram–type collapse shows S_c g^(1/5) / Q^(2/5) versus Re_Ls collapses to Y = A + B Re_Ls^(-1/3) across Newtonian and shear-thinning lower layers.
- At high Re_Ls, the curve approaches a plateau indicating inertia and gravity set the dominant scale for entrainment.
- Viscous and shear corrections rise as Re_Ls decreases, following an algebraic Re_Ls^(-1/3) scaling.
- Shear thinning renormalizes the viscous correction through an effective viscosity rather than altering the inertial baseline.
- The composite length L_s = max(l_c, a) ensures robust collapse across fluids with different surface tension and nozzle geometry.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.