Skip to main content
QUICK REVIEW

[Paper Review] Updated physics performance of the ESSnuSB experiment

A. Alekou, E. Baussan|arXiv (Cornell University)|Jun 25, 2021
Neutrino Physics ResearchPhysics and Astronomy33 references1 citations
TL;DR

This paper evaluates the physics performance of the ESSnuSB experiment, a proposed long-baseline neutrino oscillation experiment using a super-beam from the European Spallation Source. Using updated neutrino fluxes and migration matrices, it demonstrates 10σ (540 km) and 13σ (360 km) CP violation discovery sensitivity at δCP = ±90°, with 70% coverage at >5σ, and achieves high-precision measurements of δCP, mass hierarchy, and atmospheric mixing parameters.

ABSTRACT

In this paper, we present the physics performance of the ESSnuSB experiment in the standard three flavor scenario using the updated neutrino flux calculated specifically for the ESSnuSB configuration and updated migration matrices for the far detector. Taking conservative systematic uncertainties corresponding to a normalization error of $5\%$ for signal and $10\%$ for background, we find that there is $10\sigma$ $(13\sigma)$ CP violation discovery sensitivity for the baseline option of 540 km (360 km) at $\delta_{ m CP} = \pm 90^\circ$. The corresponding fraction of $\delta_{ m CP}$ for which CP violation can be discovered at more than $5 \sigma$ is $70\%$. Regarding CP precision measurements, the $1\sigma$ error associated with $\delta_{ m CP} = 0^\circ$ is around $5^\circ$ and with $\delta_{ m CP} = -90^\circ$ is around $14^\circ$ $(7^\circ)$ for the baseline option of 540 km (360 km). For hierarchy sensitivity, one can have $3\sigma$ sensitivity for 540 km baseline except $\delta_{ m CP} = \pm 90^\circ$ and $5\sigma$ sensitivity for 360 km baseline for all values of $\delta_{ m CP}$. The octant of $ heta_{23}$ can be determined at $3 \sigma$ for the values of: $ heta_{23} > 51^\circ$ ($ heta_{23} < 42^\circ$ and $ heta_{23} > 49^\circ$) for baseline of 540 km (360 km). Regarding measurement precision of the atmospheric mixing parameters, the allowed values at $3 \sigma$ are: $40^\circ < heta_{23} < 52^\circ$ ($42^\circ < heta_{23} < 51.5^\circ$) and $2.485 imes 10^{-3}$ eV$^2 < \Delta m^2_{31} < 2.545 imes 10^{-3}$ eV$^2$ ($2.49 imes 10^{-3}$ eV$^2 < \Delta m^2_{31} < 2.54 imes 10^{-3}$ eV$^2$) for the baseline of 540 km (360 km).

Motivation & Objective

  • To assess the CP violation discovery potential of the ESSnuSB experiment using updated neutrino flux and detector response simulations.
  • To evaluate the precision of δCP measurements across different baseline lengths (360 km and 540 km).
  • To determine the sensitivity of ESSnuSB to neutrino mass hierarchy and the octant of θ23.
  • To quantify the precision in measuring atmospheric mixing parameters Δm²₃₁ and θ23.
  • To evaluate the robustness of results under conservative systematic uncertainty assumptions (5% signal, 10% background normalization).

Proposed method

  • Simulates neutrino fluxes specific to the ESSnuSB configuration using updated beam and target parameters.
  • Applies updated migration matrices derived from Hyper-K geometry for the far detector response.
  • Performs a χ²-likelihood analysis to evaluate sensitivity to δCP, mass hierarchy, and θ23 octant.
  • Uses a standard three-flavor neutrino oscillation framework with parameters θ12, θ13, θ23, Δm²₂₁, Δm²₃₁, and δCP.
  • Implements conservative systematic uncertainties: 5% normalization error for signal, 10% for background.
  • Evaluates performance for both 360 km and 540 km baselines, including extended run times (up to 20 years).

Experimental results

Research questions

  • RQ1What is the CP violation discovery sensitivity of ESSnuSB at δCP = ±90° for 360 km and 540 km baselines?
  • RQ2What fraction of δCP values can be probed at >5σ significance for CP violation?
  • RQ3What is the expected 1σ precision on δCP for δCP = 0° and δCP = −90° at both baseline lengths?
  • RQ4What is the sensitivity to neutrino mass hierarchy and the octant of θ23 across the two baselines?
  • RQ5What are the 3σ allowed ranges for Δm²₃₁ and θ23 in the two baseline configurations?

Key findings

  • The ESSnuSB experiment achieves 10σ (540 km) and 13σ (360 km) sensitivity to CP violation at δCP = ±90°, with 70% of δCP values discoverable at >5σ.
  • The 1σ precision on δCP is approximately 5° for δCP = 0° and 14° (7°) for δCP = −90° at 540 km (360 km) baselines.
  • For mass hierarchy, 3σ sensitivity is achievable at 540 km baseline except at δCP = ±90°, while 5σ sensitivity is reached at 360 km for all δCP values.
  • The octant of θ23 can be determined at 3σ for θ23 > 51° (540 km) and θ23 < 42° or θ23 > 49° (360 km).
  • The 3σ allowed ranges for atmospheric parameters are 40° < θ23 < 52° and 2.485×10⁻³ eV² < Δm²₃₁ < 2.545×10⁻³ eV² (540 km), and 42° < θ23 < 51.5° and 2.49×10⁻³ eV² < Δm²₃₁ < 2.54×10⁻³ eV² (360 km).
  • Sensitivity improves significantly with longer run times: 20-year runs yield 13σ (540 km) and 15σ (360 km) CP discovery sensitivity with 76% (80%) coverage at >5σ.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.