[Paper Review] V-FCNN: Volumetric Fully Convolution Neural Network For Automatic Atrial Segmentation
This paper proposes V-FCNN, a 3D fully convolutional neural network using volumetric convolutions to enable one-shot, fully automatic atrial segmentation from late gadolinium enhancement MRI. By combining mean squared error and Dice loss, it achieves a 92.5% Dice score across 54 patients, demonstrating strong performance in the atrial mid-region despite challenges in pulmonary vein and valve plane regions.
Atrial Fibrillation (AF) is a common electro-physiological cardiac disorder that causes changes in the anatomy of the atria. A better characterization of these changes is desirable for the definition of clinical biomarkers, furthermore, thus there is a need for its fully automatic segmentation from clinical images. In this work, we present an architecture based on 3D-convolution kernels, a Volumetric Fully Convolution Neural Network (V-FCNN), able to segment the entire volume in a one-shot, and consequently integrate the implicit spatial redundancy present in high-resolution images. A loss function based on the mixture of both Mean Square Error (MSE) and Dice Loss (DL) is used, in an attempt to combine the ability to capture the bulk shape as well as the reduction of local errors products by over-segmentation. Results demonstrate a reasonable performance in the middle region of the atria along with the impact of the challenges of capturing the variability of the pulmonary veins or the identification of the valve plane that separates the atria to the ventricle. A final dice of $92.5\%$ in $54$ patients ($4752$ atria test slices in total) is shown.
Motivation & Objective
- To develop a fully automatic, one-shot method for left and right atrial segmentation from 3D late gadolinium enhancement MRI.
- To address the challenge of low tissue contrast and high anatomical variability in atrial imaging.
- To improve segmentation accuracy by leveraging 3D spatial redundancy through volumetric convolutions.
- To reduce over-segmentation and local errors via a hybrid loss function combining MSE and Dice loss.
- To simplify training and accelerate convergence by eliminating skip connections found in prior U-Net-style architectures.
Proposed method
- The V-FCNN architecture uses a 3D fully convolutional encoder-decoder structure with four 3D-convolutional blocks in both down-sampling and up-sampling paths.
- Each block applies 3D convolutions with kernel size 3×3, followed by Parametric ReLU (PReLU) and 3D batch normalization.
- The network avoids max-pooling to preserve spatial resolution and prevent information loss in small atrial structures.
- A hybrid loss function is employed: $ \text{Loss} = \text{MSE}_{\text{loss}} + \lambda \cdot \text{DICE}_{\text{loss}} $, balancing global shape accuracy and local boundary precision.
- The down-sampling path reduces spatial dimensions from 640×640×88 to 127×127×88 to fit GPU memory constraints, with input resolution reduced from original 0.625 mm³ isotropic.
- The model is trained end-to-end on 100 3D LGE-MRI scans from the 2018 Atrial Segmentation Challenge, with inference performed in a single forward pass.
Experimental results
Research questions
- RQ1Can a 3D fully convolutional network achieve robust, one-shot atrial segmentation without skip connections?
- RQ2How does a hybrid loss combining MSE and Dice loss improve segmentation accuracy compared to single-loss approaches?
- RQ3To what extent does avoiding max-pooling preserve fine anatomical details in low-contrast atrial structures?
- RQ4How does the model perform on challenging regions such as the pulmonary veins and atrioventricular valve planes?
- RQ5Can a simplified architecture without skip connections achieve competitive performance with faster training and reduced memory usage?
Key findings
- The V-FCNN achieved a mean Dice score of 92.5% across 54 test patients, with 4752 individual atrial slices evaluated.
- The highest performance was observed in the middle atrial region, with a Dice score of 94.25% (±1.28), indicating strong generalization in central atrial anatomy.
- Performance dropped in the top and bottom sections, with Dice scores of 84.48% (±2.58) and 76.33% (±7.05), respectively, due to complexity of pulmonary vein and valve plane regions.
- The hybrid loss function effectively reduced over-segmentation and improved convergence by balancing global shape fidelity (MSE) and local boundary accuracy (Dice).
- The absence of skip connections led to faster training and reduced GPU memory usage, though at the cost of slightly lower localization precision in fine structures.
- The model demonstrated robustness to image resolution reduction (from 640×640×88 to 127×127×88), though this may have contributed to the 92.5% Dice ceiling.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.