[Paper Review] Video-rate multispectral imaging in laparoscopic surgery: First-in-human application

Leonardo Ayala, Sebastian Wirkert|arXiv (Cornell University)|May 28, 2021
Optical Imaging and Spectroscopy TechniquesMedicine20 references6 citations
TL;DR

This paper presents a lightweight, video-rate multispectral imaging system integrated with a standard laparoscope for real-time perfusion monitoring during laparoscopic surgery. The system captures 16 spectral bands at 25 Hz using a snapshot multispectral camera, enabling in vivo detection of ischemia during partial nephrectomy, with UMAP-based spectral analysis successfully distinguishing perfusion changes before and during clamping.

ABSTRACT

Collection of files associated with the publication "Video-rate multispectral imaging in laparoscopic surgery: First-in-human application". It includes: 1. Sample video showing the results of tracking a region of interest from multispectral images recorded during partial nephrectomy before a clamp is applied to the renal artery (before clamping) and after clamping the artery (during clamping).

Motivation & Objective

  • To develop a compact, real-time multispectral imaging system suitable for integration into standard laparoscopic workflows.
  • To enable video-rate spectral imaging (25 Hz) with 16 spectral bands for clinical use in minimally-invasive surgery.
  • To demonstrate the feasibility of using multispectral imaging for real-time monitoring of tissue perfusion during partial nephrectomy.
  • To replace or supplement the current indocyanine green (ICG) fluorescence method, which has long washout times and limited repeatability.
  • To evaluate the potential of multispectral imaging for predicting postoperative renal function via oxygenation estimation.

Proposed method

  • A compact xiQ multispectral camera (MQ022HG-IM-SM4x4) with a 4x4 mosaic filter pattern captures 16 spectral bands in a single snapshot.
  • The system integrates with a standard 30° laparoscope and a C-Mount adapter, using a 335–610 nm bandpass filter to balance camera response across spectral bands.
  • Multispectral data are acquired at 25 Hz, with each frame containing 16 spectral bands per pixel.
  • Spectral data are normalized using ℓ₁ normalization, and UMAP dimensionality reduction is applied to project 16-dimensional spectra into 2D for visualization and clustering.
  • A random search optimizes UMAP hyperparameters (effective minimum distance and local neighborhood size), with performance evaluated via Kullback-Leibler divergence.
  • Region-of-interest (ROI) tracking is performed on in vivo data to compare spectral changes before and during vascular clamping.

Experimental results

Research questions

  • RQ1Can a video-rate multispectral imaging system be successfully integrated into a standard laparoscopic setup for real-time tissue monitoring?
  • RQ2Can multispectral imaging detect changes in kidney perfusion during partial nephrectomy, particularly during selective clamping?
  • RQ3Can UMAP-based spectral analysis effectively distinguish between pre-clamp and during-clamp tissue states in vivo?
  • RQ4Does the system outperform or offer a viable alternative to ICG fluorescence for ischemia detection in terms of repeatability and real-time feedback?
  • RQ5Can multispectral spectral signatures be used to estimate tissue oxygenation and predict postoperative renal outcomes?

Key findings

  • The system successfully acquired multispectral video at 25 Hz with a compact, lightweight design (32g, 26×26×31mm), suitable for integration into laparoscopic workflows.
  • Spectral data from kidney tissue before and during clamping were successfully clustered using UMAP, with optimal parameters found to be 0.8 for effective minimum distance and 5 for local neighborhood size.
  • The UMAP visualization revealed distinct spectral shifts corresponding to changes in tissue perfusion, indicating reliable detection of ischemia.
  • The system demonstrated feasibility for real-time perfusion monitoring in a first-in-human study during partial nephrectomy.
  • The results suggest that multispectral imaging could replace or complement ICG fluorescence, offering faster repeatability and dynamic feedback during surgery.
  • The method shows potential for predicting postoperative renal function through oxygenation estimation based on spectral signatures.