Skip to main content
QUICK REVIEW

[Paper Review] Vulnerability Assessment of Power Grids Based on Both Topological and Electrical Properties

Cunlai Pu, Pang Wu|arXiv (Cornell University)|Sep 3, 2019
Power System Reliability and MaintenanceEngineering15 references5 citations
TL;DR

This paper proposes a novel link centrality measure combining topological degree and electrical current load to assess power grid vulnerability. Using this metric, it introduces a greedy attack (LC-GA) and optimal attack (LC-OA) algorithm, demonstrating through IEEE test cases that LC-OA outperforms PSO-based and greedy methods in triggering large-scale cascading failures, with LC-GA offering a strong balance of efficiency and performance.

ABSTRACT

In modern power grids, a local failure or attack can trigger catastrophic cascading failures, which make it challenging to assess the attack vulnerability of power grids. In this Brief, we define the $K$-link attack problem and study the attack vulnerability of power grids under cascading failures. Particularly, we propose a link centrality measure based on both topological and electrical properties of power grids. According to this centrality, we propose a greedy attack algorithm and an optimal attack algorithm. Simulation results on standard IEEE bus test data show that the optimal attack is better than the greedy attack and the traditional PSO-based attack in fracturing power grids. Moreover, the greedy attack has smaller computational complexity than the optimal attack and the PSO-based attack with an adequate attack efficiency. Our work helps to understand the vulnerability of power grids and provides some clues for securing power grids.

Motivation & Objective

  • To address the limitations of purely topological centrality measures in assessing power grid vulnerability by incorporating electrical properties such as current load.
  • To define and solve the K-link attack problem, which aims to identify the most damaging set of links to trigger cascading failures.
  • To develop efficient and effective attack algorithms—greedy and optimal—based on a new link centrality metric for vulnerability assessment.
  • To validate the proposed method on standard IEEE bus test systems and compare its performance against existing PSO-based and degree/current-only approaches.

Proposed method

  • Introduces a tunable link centrality measure defined as a weighted combination of link degree and current load: $ C_{ij} = w_1 imes ext{degree}(i,j) + w_2 imes ext{current}(i,j) $, where weights $ w_1 $ and $ w_2 $ are optimized via PSO.
  • Develops a greedy attack algorithm (LC-GA) that iteratively removes the top-K links based on the proposed centrality, with $ h_1 = h_2 = 1 $.
  • Proposes an optimal attack algorithm (LC-OA) that uses PSO to globally search for the best set of K links to remove, maximizing cascading failure damage.
  • Employs a DC power flow model to compute current loads and voltage profiles, enabling accurate electrical property estimation.
  • Uses the damage metric $ heta $, defined as the ratio of total load lost to initial total load, to quantify cascading failure severity.
  • Applies PSO with parameters $ c_1 = 0.7 $, $ c_2 = 0.7 $, $ w_0 = 0.96 $, $ ext{iter}_{ ext{max}} = 30 $, and $ L = 50 ext{\%} $, to tune the centrality weights and find optimal attack sets.

Experimental results

Research questions

  • RQ1How does combining topological and electrical properties improve the identification of critical links in power grids compared to using either property alone?
  • RQ2Can a hybrid centrality measure outperform traditional link degree and current-based centrality in triggering large-scale cascading failures?
  • RQ3How does the performance of the proposed greedy attack (LC-GA) compare to the optimal attack (LC-OA) and PSO-based attack in terms of damage and computational cost?
  • RQ4Does the proposed LC-OA algorithm converge faster and achieve higher damage than PSO-OA in multiple-link attack scenarios?
  • RQ5What is the impact of initial link removal order on cascading failure propagation, and how does the greedy approach compare to global optimization?

Key findings

  • The proposed link centrality measure, which combines degree and current, achieves higher damage than both link degree and link current alone in single-link attacks across IEEE 118, 145, and 162 bus systems.
  • For multiple-link attacks, LC-OA consistently produces significantly higher damage than both LC-GA and PSO-OA, indicating superior effectiveness in triggering cascading failures.
  • LC-GA achieves a good trade-off between computational complexity and attack efficiency, with lower runtime than LC-OA and PSO-OA, and performs comparably or better than PSO-OA for $ K > 6 $ on the IEEE 162 bus system.
  • LC-OA converges faster and reaches higher damage levels than PSO-OA, with fewer iterations required, demonstrating better optimization efficiency and reduced risk of local optima.
  • The simulation results confirm that electrical current is a more informative indicator of link criticality than topological degree, validating the importance of incorporating physical power flow characteristics.
  • The K-link attack problem is proven to be NP-complete, justifying the use of heuristic and metaheuristic approaches like PSO for optimal attack set identification.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.