Skip to main content
QUICK REVIEW

[Paper Review] A Framework for Frequency Stability Assessment of Future Power Systems: An Australian Case Study

Ahmad Shabir Ahmadyar, Shariq Riaz|arXiv (Cornell University)|Aug 1, 2017
Power System Optimization and StabilityEngineering12 references5 citations
TL;DR

This paper proposes a time-series frequency stability assessment framework for future power systems with high non-synchronous renewable penetration, using extensive scenario simulations to identify stability limits and optimize system resilience. The key contribution is a dynamic inertia constraint that ensures frequency stability across all credible contingencies, with de-loaded wind farms providing the most effective frequency support via governor-like response.

ABSTRACT

The increasing penetration of non-synchronous renewable energy sources (NS-RES) alters the dynamic characteristic, and consequently, the frequency behaviour of a power system. To accurately identify these changing trends and address them in a systematic way, it is necessary to assess a large number of scenarios. Given this, we propose a frequency stability assessment framework based on a time-series approach that facilitates the analysis of a large number of future power system scenarios. We use this framework to assess the frequency stability of the Australian future power system by considering a large number of future scenarios and sensitivity of different parameters. By doing this, we identify a maximum non-synchronous instantaneous penetration range from the frequency stability point of view. Further, to reduce the detrimental impacts of high NS-RES penetration on system frequency stability, a dynamic inertia constraint is derived and incorporated in the market dispatch model. The results show that such a constraint guarantees frequency stability of the system for all credible contingencies. Also, we assess and quantify the contribution of synchronous condensers, synthetic inertia of wind farms and a governor-like response from de-loaded wind farms on system frequency stability. The results show that the last option is the most effective one.

Motivation & Objective

  • To address the challenge of assessing frequency stability in future power systems with high penetration of non-synchronous renewable energy sources (NS-RES), which disrupt traditional stability assessment methods.
  • To identify the maximum non-synchronous instantaneous penetration (NSIP) range that maintains system frequency stability under diverse future scenarios.
  • To develop and integrate a dynamic inertia constraint into the market dispatch model to ensure frequency stability across all credible contingencies.
  • To quantify and compare the effectiveness of conventional and non-conventional frequency support resources—synchronous condensers, synthetic inertia, and governor-like wind farm control—on system frequency response.
  • To evaluate the impact of load models and inertia location on system frequency stability through sensitivity analysis.

Proposed method

  • A time-series simulation framework is developed to analyze a large number of future power system scenarios, incorporating stochastic variations in NS-RES generation and load.
  • The framework evaluates system frequency response using key metrics: rate of change of frequency (RoCoF) and frequency nadir, under various contingency conditions.
  • A dynamic inertia constraint is formulated and embedded into the market dispatch model to enforce minimum system inertia levels in real time, based on system conditions.
  • Three key frequency support options are modeled: synchronous condensers (SC), inertia emulation (IE) in wind farms, and de-loading (DL) of wind farms for governor-like response.
  • The simulation uses a full year of high-resolution data (e.g., 1-hour resolution) to assess performance across different seasons and operational conditions.
  • Sensitivity analysis is performed on load models and inertia distribution to assess their impact on RoCoF and frequency nadir.

Experimental results

Research questions

  • RQ1What is the maximum non-synchronous instantaneous penetration (NSIP) level that the Australian future power system can tolerate without violating frequency stability criteria?
  • RQ2How do different system parameters—such as load model and inertia location—affect frequency stability under high NS-RES penetration?
  • RQ3What is the relative effectiveness of synchronous condensers, synthetic inertia from wind farms, and governor-like response from de-loaded wind farms in improving frequency stability?
  • RQ4Can a dynamic inertia constraint in the market dispatch model guarantee frequency stability across all credible contingencies?
  • RQ5How does the choice of frequency support strategy impact RoCoF, frequency nadir, and settling frequency?

Key findings

  • The maximum non-synchronous instantaneous penetration (NSIP) range that maintains frequency stability is identified as a critical threshold, beyond which system frequency control becomes unstable.
  • The dynamic inertia constraint, when enforced in the market dispatch model, guarantees frequency stability for all credible contingencies, ensuring RoCoF remains within safe limits.
  • De-loaded wind farms (DL) provide the most effective frequency support, improving both RoCoF and frequency nadir, and also enhancing settling frequency due to combined kinetic energy release and governor-like control.
  • Synchronous condensers (SC) offer the most effective RoCoF performance due to their natural, instantaneous inertial response, outperforming synthetic inertia and de-loading in this metric.
  • Inertia emulation (IE) in wind farms improves RoCoF but can lead to a second frequency nadir due to kinetic energy extraction and delayed recovery, worsening the nadir in some hours compared to the base case.
  • The implementation of the dynamic inertia constraint results in wind energy curtailment—263 GW·h annually—compared to 380 GW·h under a simpler inertia constraint, but enables coordinated, system-wide frequency support.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.