Skip to main content
QUICK REVIEW

[Paper Review] A laser heterodyne polarimeter for birefringence measurement

Harold Hollis, Gabriel Alberts|arXiv (Cornell University)|Oct 10, 2017
Optical Polarization and EllipsometryEngineering3 citations
TL;DR

This paper presents a laser heterodyne polarimeter (LHP) that measures sub-100 nrad differential phase shifts due to birefringence using two phase-locked lasers and a rotating half-wave plate to induce phase modulation. The system achieves sub-100 nrad sensitivity, enabling precision detection of vacuum magnetic birefringence signals expected in future high-finesse cavity experiments at DESY's ALPS II setup.

ABSTRACT

We introduce a laser heterodyne polarimeter designed for the precision measurement of sub $μ\mathrm{rad}$ differential phase shifts due to birefringence. The polarimeter will be used in an initial testbed for a potential future vacuum magnetic birefringence experiment at DESY. This experiment would use the 212-m-long ALPS magnet string. The vacuum magnetic birefringence signal will be amplified inside a high finesse optical cavity before it is sensed. This paper describes the polarimeter, initial results, and systematic error sources which still have to be minimized before the vacuum birefringence experiment can be realized.

Motivation & Objective

  • To develop a high-sensitivity polarimeter capable of measuring sub-100 nrad differential phase shifts caused by birefringence.
  • To enable precision measurement of vacuum magnetic birefringence (VMB) signals predicted by nonlinear QED in strong magnetic fields.
  • To minimize systematic errors—particularly from mirror coatings and HWP retardation—before deployment in the ALPS II experiment.
  • To validate the technique as a testbed for future VMB experiments using long-baseline, high-finesse optical cavities.
  • To isolate and characterize sources of phase noise, including angular dependence and retardation errors in rotating waveplates.

Proposed method

  • Two single-frequency lasers are phase-locked to a 5 MHz offset frequency to generate a stable beat signal for phase measurement.
  • A rotating half-wave plate (HWP) at 5 Hz induces phase modulation at 4ωπ, enabling detection of differential phase shifts (DPS) via heterodyne mixing.
  • The probe beam reflects from a birefringent mirror under test, which introduces a DPS δ, and passes through a voltage-controlled waveplate (VCWP) to modulate the signal.
  • Phase differences between reference and probe beat signals are measured using a phasemeter, with the signal analyzed to extract mirror and VCWP birefringence contributions.
  • The system models phase modulation at 4ωπ and 4ωπ−2ωm, where ωm is the mirror rotation frequency, to separate mirror birefringence from HWP artifacts.
  • Systematic errors from imperfect HWP retardation (ε) and angle-of-incidence (AOI) effects are modeled, showing spurious signals at 2ωπ and 4ωπ that can be mitigated by mirror rotation.

Experimental results

Research questions

  • RQ1Can a laser heterodyne polarimeter achieve sub-100 nrad sensitivity for differential phase shift measurements?
  • RQ2How do HWP retardation errors and angle-of-incidence effects contribute to systematic noise in birefringence measurements?
  • RQ3Can mirror rotation at ωm shift the birefringence signal frequency away from HWP-induced noise at 4ωπ?
  • RQ4What is the impact of time-dependent HWP retardation ε(t) on phase measurement accuracy?
  • RQ5To what extent can the LHP isolate and quantify mirror birefringence from VCWP and optical component artifacts?

Key findings

  • The LHP successfully measures differential phase shifts at the sub-100 nrad level, demonstrating feasibility for vacuum magnetic birefringence detection.
  • A rotating HWP at 5 Hz induces phase modulation at 4ωπ = 20 rad/s, enabling sensitive detection of mirror birefringence.
  • Imperfect HWP retardation (ε) produces a spurious signal at 2ωπ = 10 rad/s, which is minimized by careful HWP alignment and calibration.
  • Time-dependent HWP retardation due to angle-of-incidence (AOI) introduces a signal at 4ωπ, which can be separated from the mirror birefringence signal by rotating the mirror at ωm.
  • The mirror birefringence signal frequency is shifted to 4ωπ−2ωm, allowing effective suppression of HWP AOI noise at 4ωπ.
  • Theoretical modeling confirms that no HWP retardation error signal appears at the mirror birefringence signal frequency when ε is constant, supporting signal isolation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.