TL;DR

This paper proposes a convex, algorithm-independent capacity characterization for aggregations of Thermostatically Controlled Loads (TCLs) that accounts for temperature, cycling, and energy constraints. By modeling fractional load states to eliminate integer cycle constraints, the method enables grid operators to plan feasible, optimizable reference trajectories that ensure high tracking accuracy and compliance with individual TCL quality-of-service limits, outperforming prior methods by two orders of magnitude in tracking error when cycling constraints are ignored.

ABSTRACT

Thermostatically Controlled Loads (TCLs) such as air conditioners and water heaters typically maintain their temperature within a preset range using on/off actuation. These types of loads are inherently flexible: many different power consumption trajectories exist that can keep the temperature within range. Decades of research has shown that flexible loads can provide valuable grid services. Quantifying the power and energy capacities of a collection of TCLs is a well-studied problem. However, most works focus on temperature constraints. In this work, we present a characterization of the capacity of a collection of TCLs that considers not only temperature, but also cycling and energy constraints. The characterization leads to a set of convex constraints. A grid operator can use this characterization to compute a feasible power consumption trajectory for an ensemble of TCLs that comes closest to what the operator needs to maintain demand-supply balance. Unlike prior attempts at capacity characterizations incorporating cycling constraints, our results are independent of the algorithm used to coordinate the TCLs.

Motivation & Objective

  • To address the gap in existing capacity characterizations that neglect cycling constraints in TCL ensembles.
  • To develop a grid operator-ready method for planning feasible, high-fidelity reference power trajectories for TCL collections.
  • To ensure that reference signals are compatible with individual TCL quality-of-service (QoS) constraints, including temperature, cycling frequency, and energy use.
  • To create a convex optimization framework for reference planning that is independent of the coordination algorithm used.
  • To demonstrate robustness and effectiveness of the method under heterogeneous TCL conditions and realistic weather profiles.

Proposed method

  • The method models the fraction of TCLs in on/off states to convert discrete, integer cycle constraints into continuous, convex constraints on aggregate behavior.
  • It formulates aggregate capacity as a set of convex constraints derived from individual TCL parameters: COP, temperature bounds, minimum on/off times, and energy limits.
  • The reference planning problem is cast as a convex optimization problem that minimizes deviation from a target power trajectory while respecting the derived aggregate constraints.
  • The approach assumes quasi-homogeneity of TCLs but demonstrates robustness to heterogeneity in numerical experiments.
  • The method is validated via closed-loop simulations comparing tracking performance against a baseline method that ignores cycling constraints.
  • The framework enables any well-designed coordination algorithm to track the reference without violating individual TCL QoS.

Experimental results

Research questions

  • RQ1Can a convex, algorithm-independent capacity characterization be developed for TCL ensembles that includes cycling constraints?
  • RQ2What is the impact of ignoring cycling constraints in reference planning on tracking performance and QoS compliance?
  • RQ3How robust is the proposed capacity characterization to deviations from the quasi-homogeneity assumption in real-world TCL populations?
  • RQ4Can the proposed method ensure high-fidelity reference tracking while respecting all individual TCL constraints?
  • RQ5What is the trade-off between reference aggressiveness and TCL cycling frequency when cycling constraints are not considered?

Key findings

  • The proposed method reduces reference tracking error to 0.06% in closed-loop simulations, compared to 24% when using a prior method that ignores cycling constraints.
  • The reference signal planned with the proposed method is less aggressive, avoiding excessive ramp rates that would otherwise violate TCL cycling limits.
  • All TCLs in the simulation satisfy their individual cycling constraints (≤10 minutes between cycles), with most operating near the 20-minute cycle period.
  • The method remains robust to heterogeneity in TCL parameters, as shown by consistent performance across diverse load distributions.
  • The convex formulation ensures that any feasible reference signal generated is trackable by any coordination algorithm respecting the three QoS constraints.
  • Numerical results confirm that neglecting cycling constraints leads to infeasible or poorly tracked references, undermining grid reliability and user satisfaction.