TL;DR

This paper proposes an eikonal model with re-excitability for fast, real-time simulation of cardiac arrhythmias, using a modified fast marching method (FMM) that incorporates tissue restitution properties derived from the monodomain model. The approach accurately captures re-entrant dynamics in both atria and ventricles while handling anisotropy and heterogeneity, achieving potential real-time performance on standard desktop hardware.

ABSTRACT

Precision cardiology based on cardiac digital twins requires accurate simulations of cardiac arrhythmias. However, detailed models, such as the monodomain model, are computationally costly and have limited applicability in practice. Thus, it desirable to have fast models that can still represent the main physiological features presented during cardiac arrhythmias. The eikonal model is an approximation of the monodomain model that is widely used to describe the arrival times of the electrical wave. However, the standard eikonal model does not generalize to the complex re-entrant dynamics that characterize the cardiac arrhythmias. In this work, we propose an eikonal model that includes the tissue re-excitability, which allows to describe re-entries. The re-excitability properties are inferred from the monodomain model. Our eikonal model also handles the tissue anisotropy and heterogeneity. We compare the eikonal model to the monodomain model in various numerical experiments in the atria and the ventricles. The eikonal model is qualitatively accurate in the simulation of re-entries and can be potentially ran in real-time, opening the door to its clinical applicability.

Motivation & Objective

  • To develop a fast, clinically applicable model for simulating re-entrant cardiac arrhythmias like atrial fibrillation and ventricular tachycardia.
  • To extend the standard eikonal model—which only simulates single-wave activation—by incorporating tissue re-excitability to enable multiple activations.
  • To ensure the model handles tissue anisotropy and heterogeneity, critical for realistic electrophysiological simulations.
  • To achieve real-time performance suitable for patient-specific planning without high-performance computing resources.
  • To validate the model’s accuracy against the high-fidelity monodomain model in complex arrhythmia scenarios.

Proposed method

  • Adapt the fast marching method (FMM) to include re-excitability by introducing a global time variable and alternating updates of activation times and restitution properties.
  • Use restitution curves computed from monodomain simulations to define the time-dependent refractoriness of cardiac tissue.
  • Apply mesh adaptation with anisotropic elements to ensure convergence of the FMM to the viscosity solution of the eikonal equation.
  • Implement the FMM on triangulated surfaces (2D) and extendable to tetrahedral meshes (3D), using Mmg software for anisotropic mesh generation.
  • Integrate tissue heterogeneity effects through spatially varying conduction velocity and restitution parameters derived from monodomain data.
  • Use a single-pass, monotonic FMM algorithm to ensure numerical stability and correct propagation ordering during re-excitation cycles.

Experimental results

Research questions

  • RQ1Can an eikonal model with re-excitability accurately simulate re-entrant wave dynamics observed in atrial fibrillation and ventricular tachycardia?
  • RQ2How can the fast marching method be modified to handle time-dependent tissue properties like restitution without compromising computational efficiency?
  • RQ3To what extent does the inclusion of anisotropy and heterogeneity improve the realism of eikonal simulations compared to standard models?
  • RQ4Is the proposed model capable of real-time performance on standard desktop hardware, enabling clinical use?
  • RQ5How does the computational cost of the re-excitability extension scale, and can it be optimized to achieve real-time operation?

Key findings

  • The proposed eikonal model with re-excitability qualitatively reproduces complex re-entrant activation patterns in both atria and ventricles, matching key features of the monodomain model.
  • The FMM implementation with re-excitability runs in 83.86 seconds for a 15 cm × 15 cm tissue with 0.05 cm resolution, though this is not optimized; a C++-based version is estimated to be real-time.
  • The computational complexity remains O(N log N), indicating that the re-excitability extension adds negligible overhead to the FMM algorithm.
  • The model achieves accurate simulation of conduction velocity (68 cm/s) and activation timing, with results comparable to the monodomain model in re-entry scenarios.
  • Mesh adaptation with anisotropic elements ensures convergence to the viscosity solution, improving accuracy in directionally dependent conduction.
  • The training phase—requiring conduction velocity tuning, mesh adaptation, and restitution curve computation—is computationally negligible compared to full monodomain simulations, justifying its use in patient-specific planning.