Skip to main content
QUICK REVIEW

[Paper Review] Code Minimization for Fringe Projection Based 3D Stereo Sensors by Calibration Improvement

Christian Bräuer-Burchardt, Peter Kühmstedt|arXiv (Cornell University)|Apr 29, 2014
Optical measurement and interference techniquesComputer Science3 references4 citations
TL;DR

This paper presents a method to eliminate the need for Gray code or other phase-unwrapping codes in fringe projection 3D stereo sensors by leveraging double triangulation and improved projector calibration. The approach achieves near-complete 3D reconstruction (up to 99.5% completeness) with minimal false positives (as low as 1.0%) after calibration, enabling real-time applicability without additional coding sequences.

ABSTRACT

Code minimization provides a speed-up of the processing time of fringe projection based stereo sensors and possibly makes them real-time applicable. This paper reports a methodology which enables such sensors to completely omit Gray code or other additional code. Only a sequence of sinusoidal images is necessary. The code reduction is achieved by involvement of the projection unit into the measurement, double triangulation, and a precise projector calibration or significant projector calibration improvement, respectively.

Motivation & Objective

  • To eliminate the need for additional phase-unwrapping codes such as Gray code in fringe projection 3D sensors.
  • To enable real-time 3D measurement by reducing projection sequence length and processing time.
  • To improve measurement completeness and reduce false positives through enhanced projector calibration.
  • To achieve geometric phase unwrapping using double triangulation with minimal reliance on external coding.
  • To evaluate the impact of projector calibration accuracy on 3D reconstruction quality and false positive rates.

Proposed method

  • Uses only sinusoidal fringe patterns, omitting any additional code such as Gray code.
  • Employs double triangulation: one using two cameras (CC-mode) and one using a camera and the projector (CP-mode).
  • Generates 3D point candidates from both CC-mode and CP-mode, then matches them to resolve ambiguities.
  • Applies epipolar geometry to constrain the search space for corresponding phase values, reducing computational load.
  • Implements a threshold-based matching criterion (thr) to filter false positives, with thr set in radians.
  • Performs extensive projector calibration, including distortion correction, to reduce baseline error and improve triangulation accuracy.

Experimental results

Research questions

  • RQ1Can phase unwrapping be achieved without additional coding sequences in fringe projection 3D sensors?
  • RQ2How does projector calibration improvement affect the accuracy and completeness of 3D reconstruction?
  • RQ3What is the impact of double triangulation on false positive detection and point uniqueness?
  • RQ4Can the method achieve real-time performance by eliminating code sequences?
  • RQ5How do different threshold values (thr) influence the trade-off between completeness and false positive rate?

Key findings

  • After calibration improvement, the method achieved 99.1% completeness and 1.5% false positives for the Schiller bust with thr = 0.01π.
  • For the pyramid stump, completeness reached 99.5% with only 0.0% false positives under optimal conditions.
  • The average 3D point distance error (cpd_mn) decreased from 1.1 mm (before calibration) to 0.2 mm (after calibration).
  • Epipolar line error was reduced to less than 0.1 pixel, confirming accurate geometric alignment.
  • The standard deviation of 3D point measurements was 11 μm for the bust and 9 μm for the stump, indicating high precision.
  • Mode m1 achieved fewer false positives but slightly lower completeness than mode m2, allowing user preference-based selection.