[Paper Review] Computational fluid dynamic simulation of hull reservoir wave energy device
This study presents a CFD-based simulation of a novel Hull Reservoir Wave Energy Converter (HRWEC) that harnesses wave energy through hull pitch motion and internal flap rotation driven by sloshing water. Using ANSYS-AQWA and ANSYS-FLUENT, the researchers analyzed hydrodynamic performance under regular waves, identifying case 3 (3.0 m³ internal water volume) as optimal, achieving a 53.2% maximum capture factor—surpassing the reference case—highlighting the critical role of internal water level in efficiency optimization.
This paper presents a Computational Fluid Dynamics (CFD) analysis of a wave energy device called the Hull Reservoir Wave Energy Converter (HRWEC). The device consists of a floating hull and a flap connected to the shaft of power take-off system (PTO), which is integral to the hull structure. It is unique due to its ability to convert wave energy by utilizing the pitch motion of the hull and rotating flap due to the internal water movement in the hull. Due to the complexity of the internal fluid dynamics, a CFD-based analysis was considered most appropriate. The CFD investigation of the dynamics of the device was done under regular wave conditions by using the ANSYS-AQWA and ANSYS FLUENT. Relative pitch angle variation, the hydrodynamic coefficients, which determine the degree of power extraction, were obtained from simulated results. A simulation was designed exhibiting complete system dynamics for different configurations varying on internal water height. Excellent convergence was observed,and an optimum configuration was identified. It is expected to validate the simulation results through experiments in the foreseeable future.
Motivation & Objective
- To evaluate the hydrodynamic performance of a novel Hull Reservoir Wave Energy Converter (HRWEC) using computational fluid dynamics.
- To investigate how internal water volume affects power extraction efficiency and device dynamics.
- To validate the CFD simulation approach by comparing results with experimental data from the PeWEC device.
- To identify the optimal internal water level and PTO damping coefficient that maximize energy capture.
Proposed method
- Employed ANSYS-AQWA to simulate wave-body interaction and hydrodynamic coefficients under regular wave conditions.
- Used ANSYS-FLUENT to model internal fluid sloshing dynamics and extract forces and moments on the flap and hull.
- Conducted simulations across four cases with varying internal water volumes (0–3.5 m³) to assess performance trade-offs.
- Calculated capture factor as a function of PTO damping coefficient to determine optimal damping for maximum energy extraction.
- Validated the CFD model by comparing simulated capture factors with experimental results from the PeWEC device.
- Analyzed turbulence effects and energy dissipation to assess the impact of internal fluid on system efficiency.
Experimental results
Research questions
- RQ1How does the inclusion of internal water in the HRWEC hull affect its hydrodynamic performance and power capture efficiency?
- RQ2What is the optimal internal water volume that maximizes the capture factor under regular wave conditions?
- RQ3How does the PTO damping coefficient influence the capture factor, and what is the optimal value for maximum energy extraction?
- RQ4To what extent does the CFD simulation model accurately replicate real-world device behavior, as validated against experimental PeWEC data?
- RQ5How do internal fluid forces, such as drag and moment, vary with different water volumes and what is their impact on system dynamics?
Key findings
- Case 3, with 3.0 m³ of internal water, achieved the highest maximum capture factor of 53.2%, outperforming the reference case (49.8%) and other configurations.
- The capture factor initially increases with PTO damping coefficient, peaks, and then declines, indicating a clear optimal damping value for each configuration.
- Case 2 (2.5 m³ water) showed the best overall performance among non-reference cases, achieving a 42% capture factor at optimal damping.
- The reference case (no internal water) had a maximum capture factor of 49.8%, confirming the CFD model's validity through comparison with experimental PeWEC data.
- Internal fluid inclusion reduced energy dissipation and altered hydrodynamic forces, with drag decreasing and moment behavior becoming more complex as water volume increased.
- The simulation demonstrated excellent convergence and reliability, supporting future experimental validation of the HRWEC design.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.