TL;DR

CoRRECT is a deep unfolding framework that jointly reconstructs motion-corrupted, accelerated multi-contrast GRE MRI data and estimates artifact-free R2* maps by integrating physical MRI models, biophysical signal models, and learned priors. It achieves state-of-the-art performance in motion and inhomogeneity artifact suppression without requiring pre-computed correction parameters, even under high acceleration rates (up to ×8) on real experimental data.

ABSTRACT

Quantitative MRI (qMRI) refers to a class of MRI methods for quantifying the spatial distribution of biological tissue parameters. Traditional qMRI methods usually deal separately with artifacts arising from accelerated data acquisition, involuntary physical motion, and magnetic-field inhomogeneities, leading to suboptimal end-to-end performance. This paper presents CoRRECT, a unified deep unfolding (DU) framework for qMRI consisting of a model-based end-to-end neural network, a method for motion-artifact reduction, and a self-supervised learning scheme. The network is trained to produce R2* maps whose k-space data matches the real data by also accounting for motion and field inhomogeneities. When deployed, CoRRECT only uses the k-space data without any pre-computed parameters for motion or inhomogeneity correction. Our results on experimentally collected multi-Gradient-Recalled Echo (mGRE) MRI data show that CoRRECT recovers motion and inhomogeneity artifact-free R2* maps in highly accelerated acquisition settings. This work opens the door to DU methods that can integrate physical measurement models, biophysical signal models, and learned prior models for high-quality qMRI.

Motivation & Objective

  • Address the limitations of conventional qMRI methods that treat motion, field inhomogeneity, and accelerated acquisition as separate problems.
  • Develop an end-to-end deep learning framework that jointly optimizes MRI reconstruction and R2* estimation under realistic artifacts.
  • Enable training without ground-truth R2* maps by leveraging a self-supervised learning scheme based on k-space consistency.
  • Integrate physical measurement models, biophysical signal models, and learned regularization into a unified deep unfolding architecture.
  • Achieve robust performance on real motion-corrupted, highly accelerated mGRE data without pre-processing correction steps.

Proposed method

  • Formulates the MRI reconstruction and R2* estimation as a deep unfolding network that alternates between data consistency and prior modeling steps.
  • Uses a model-based end-to-end neural network architecture where each layer corresponds to a step in an iterative optimization algorithm.
  • Incorporates motion and field inhomogeneity models into the forward operator during training to simulate realistic artifacts.
  • Employs a self-supervised loss function that enforces consistency between predicted k-space data and measured k-space data, without requiring ground-truth R2* maps.
  • Trains the network using simulated data with realistic motion and field inhomogeneity, enabling generalization to real experimental data.
  • Deploys the trained network using only raw k-space data at inference, eliminating the need for pre-computed motion or field maps.

Experimental results

Research questions

  • RQ1Can a unified deep unfolding framework jointly reconstruct motion-corrupted, accelerated mGRE data and estimate artifact-free R2* maps?
  • RQ2How well can a self-supervised training scheme perform when ground-truth R2* maps are unavailable?
  • RQ3To what extent does integrating physical and biophysical models improve robustness to motion and field inhomogeneity artifacts?
  • RQ4Can the framework generalize to real experimental data with unpredictable motion patterns not seen during training?
  • RQ5Does joint optimization of reconstruction and parameter estimation outperform decoupled pipelines in terms of image quality and accuracy?

Key findings

  • CoRRECT successfully removes motion and field inhomogeneity artifacts from mGRE data even at acceleration rates up to ×8, as demonstrated on real experimental data.
  • The method achieves superior visual quality and structural preservation in reconstructed mGRE images and R2* maps compared to baseline methods such as ZF+NLLS, TV, RED, and DU.
  • CoRRECT outperforms all baselines in artifact suppression, sharpness, and contrast, particularly in regions with strong motion-induced distortions (evident in zoomed-in regions and blue-arrowed areas).
  • The framework maintains consistent performance across different brain slices with varying motion patterns, demonstrating robustness and generalization to diverse in vivo motion corruption.
  • CoRRECT achieves high-quality R2* estimation directly from subsampled, noisy, and motion-corrupted k-space data without requiring pre-computed motion or field maps.
  • The self-supervised training scheme enables effective learning without ground-truth R2* maps, making the method applicable to real-world clinical data where such labels are unavailable.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.