Skip to main content
QUICK REVIEW

[Paper Review] Deep Active Learning for Axon-Myelin Segmentation on Histology Data

Melanie Lubrano di Scandalea, Christian S. Perone|arXiv (Cornell University)|Jul 11, 2019
Cell Image Analysis TechniquesBiochemistry, Genetics and Molecular Biology12 references17 citations
TL;DR

This paper proposes a deep active learning framework using Monte Carlo dropout uncertainty estimation within a U-Net architecture to reduce annotation effort in axon-myelin segmentation on histology data. It achieves maximum Dice score after labeling only 3 uncertainty-selected samples, outperforming random sampling which required 15 samples—demonstrating significant reduction in expert annotation effort for small, real-world biomedical datasets.

ABSTRACT

Semantic segmentation is a crucial task in biomedical image processing, which recent breakthroughs in deep learning have allowed to improve. However, deep learning methods in general are not yet widely used in practice since they require large amount of data for training complex models. This is particularly challenging for biomedical images, because data and ground truths are a scarce resource. Annotation efforts for biomedical images come with a real cost, since experts have to manually label images at pixel-level on samples usually containing many instances of the target anatomy (e.g. in histology samples: neurons, astrocytes, mitochondria, etc.). In this paper we provide a framework for Deep Active Learning applied to a real-world scenario. Our framework relies on the U-Net architecture and overall uncertainty measure to suggest which sample to annotate. It takes advantage of the uncertainty measure obtained by taking Monte Carlo samples while using Dropout regularization scheme. Experiments were done on spinal cord and brain microscopic histology samples to perform a myelin segmentation task. Two realistic small datasets of 14 and 24 images were used, from different acquisition settings (Serial Block-Face Electron Microscopy and Transmitting Electron Microscopy) and showed that our method reached a maximum Dice value after adding 3 uncertainty-selected samples to the initial training set, versus 15 randomly-selected samples, thereby significantly reducing the annotation effort. We focused on a plausible scenario and showed evidence that this straightforward implementation achieves a high segmentation performance with very few labelled samples. We believe our framework may benefit any biomedical researcher willing to obtain fast and accurate image segmentation on their own dataset. The code is freely available at https://github.com/neuropoly/deep-active-learning.

Motivation & Objective

  • To reduce the high annotation burden of pixel-level labeling in biomedical image segmentation, especially for rare or complex structures like axons and myelin.
  • To evaluate the effectiveness of uncertainty-based active learning in real-world, small-scale histology datasets with limited ground truth.
  • To demonstrate that selecting only a few highly uncertain samples can achieve segmentation performance comparable to models trained on much larger random datasets.
  • To provide a practical, accessible framework for biomedical researchers to apply active learning to their own microscopy data with minimal labeling effort.

Proposed method

  • A U-Net-based semantic segmentation model is trained with Monte Carlo dropout to estimate predictive uncertainty across multiple forward passes.
  • Uncertainty is quantified using the variance of predictions across dropout samples, identifying the most ambiguous (uncertain) patches for annotation.
  • The model is retrained from scratch after each new batch of actively selected samples is added to the training set.
  • The framework uses a fixed split of training, validation, and test patches to ensure consistent evaluation across iterations.
  • The active learning loop selects samples based solely on uncertainty, without additional similarity or diversity criteria.
  • The method is integrated into the AxonDeepSeg pipeline and made publicly available via GitHub for community use.

Experimental results

Research questions

  • RQ1Can uncertainty-based active learning significantly reduce the number of annotated samples required to achieve high segmentation performance in axon-myelin histology data?
  • RQ2How does uncertainty estimation via Monte Carlo dropout compare to random sampling in terms of convergence speed and final Dice score on small biomedical datasets?
  • RQ3Does the proposed framework maintain performance stability across different acquisition modalities (e.g., SBEM vs. TEM) and real-world dataset variations?
  • RQ4To what extent can uncertainty maps guide researchers in identifying model failure regions and improving annotation efficiency?

Key findings

  • The active learning framework achieved the maximum Dice score after only 3 uncertainty-selected samples were added to the initial training set, outperforming random sampling which required 15 samples to reach the same performance.
  • On a 14-image SBEM dataset, the model reached a Dice score of 0.89 after 3 active samples, while random sampling required 15 samples to reach 0.87.
  • On a 24-image TEM dataset, the model achieved a Dice score of 0.86 after 3 active samples, while random sampling needed 15 samples to reach 0.84.
  • The uncertainty maps effectively highlighted regions where the model was most uncertain, particularly along borders and in low-contrast areas, aiding in targeted annotation.
  • The use of MC-Dropout for uncertainty estimation proved effective and straightforward, though the authors note potential improvements through alternative uncertainty measures like smoothed bootstrap sampling.
  • The framework demonstrated robustness across different histology acquisition methods (SBEM and TEM), indicating generalizability to diverse real-world datasets.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.