Skip to main content
QUICK REVIEW

[Paper Review] Detection of polystyrene sphere translocations using resizable elastomeric nanopores

Geoff R. Willmott, Lara H. Bauerfeind|arXiv (Cornell University)|Feb 2, 2010
Nanopore and Nanochannel Transport StudiesEngineering1 references7 citations
TL;DR

This study demonstrates the detection of 200 nm and 800 nm carboxylated polystyrene spheres translocating through resizable elastomeric nanopores using ionic current pulses. The key contribution is a robust, non-destructive method for estimating pore size based on absolute pulse height, with the narrowest pore radius being the dominant factor, validated across variable strain, voltage, and particle concentration.

ABSTRACT

Resizable elastomeric nanopores have been used to measure pulses of ionic current caused by carboxylated polystyrene spheres of diameter 200 nm and 800 nm. The nanopores represent a novel technology which enables nanoscale resizing of a pore by macroscopic actuation of an elastomeric membrane. Three different pores were employed with variable applied strain, transmembrane potential, particle concentration and sphere radius. Theory describing current pulse magnitude has been extended to conical pore geometry. A consistent method for interpretation of data close to the noise threshold has been introduced, and experimental data has been used to compare several methods for efficient, non-destructive calculation of pore dimensions. The most effective models emphasize the absolute pulse size, which is predominantly determined by the opening radius at the narrowest part of the roughly conical pores, rather than the profile along the entire pore length. Experiments were carried out in a regime for which both electro-osmotic and electrophoretic transport are significant.

Motivation & Objective

  • To demonstrate the feasibility of using resizable elastomeric nanopores for single-particle translocation sensing.
  • To investigate the influence of pore geometry, applied strain, transmembrane potential, and particle concentration on ionic current signals.
  • To compare theoretical models for interpreting resistance pulse data and identify the most accurate, non-destructive method for pore sizing.
  • To address challenges in distinguishing true translocation events from noise and background activity in dynamic, variable-pore systems.
  • To evaluate the roles of electrophoretic and electro-osmotic transport in particle movement through conical nanopores.

Proposed method

  • Resealable elastomeric nanopores were fabricated in an elastomeric membrane and actuated via macroscopic strain to vary pore size across a range of diameters.
  • Ionic current measurements were recorded during translocation of 200 nm and 800 nm carboxylated polystyrene spheres under varying transmembrane potentials and particle concentrations.
  • A theoretical model was extended to conical pore geometry, incorporating electrokinetic effects including electrophoretic and electro-osmotic flows.
  • Pulse height analysis focused on the maximum blockade current, with models emphasizing the absolute pulse magnitude as the primary indicator of pore size.
  • A consistent noise threshold was applied across all experiments to identify modal translocation peaks and distinguish true events from background fluctuations.
  • Multiple theoretical models were compared using experimental data to assess accuracy in estimating the narrowest pore radius without destructive characterization.

Experimental results

Research questions

  • RQ1How do variations in applied strain, transmembrane potential, and particle concentration affect ionic current pulses during polystyrene sphere translocation?
  • RQ2Which theoretical model most accurately predicts pore size from resistance pulse data in resizable nanopores?
  • RQ3To what extent do electrophoretic and electro-osmotic forces govern particle transport in conical elastomeric nanopores?
  • RQ4Can absolute pulse height alone provide a reliable, non-destructive estimate of the narrowest pore radius?
  • RQ5How can translocation events be reliably distinguished from noise and non-translocating particle activity in a dynamically variable system?

Key findings

  • The magnitude of resistance pulses increased with baseline pore resistance, indicating clearer signals for smaller pores, consistent with Ohmic behavior.
  • Pulse size scaled approximately with particle volume, showing a significant increase from 200 nm to 800 nm spheres, supporting volumetric scaling predictions.
  • There was little dependence of pulse size on applied voltage, confirming a predominantly Ohmic I-V relationship in the experimental regime.
  • The most accurate pore size estimation was achieved using models based on absolute pulse height, particularly when the particle was at the narrowest part of the pore.
  • Theoretical models emphasizing the narrowest pore radius outperformed those relying on full pore profile integration, indicating that local geometry dominates signal interpretation.
  • Experimental scatter was attributed to the dynamic, variable-pore nature of the system, highlighting the need for improved characterization of internal pore geometry and surface charge effects.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.