[Paper Review] Diffusion Models for Contrast Harmonization of Magnetic Resonance Images
This paper proposes a diffusion model-based method for contrast harmonization in T1.5T and T3T magnetic resonance images, using paired scans to translate source contrast to target contrast while preserving anatomical structure. The approach achieves superior segmentation consistency and Hausdorff distance performance compared to GAN-based methods, especially for 1.5T-to-3T mapping, with improved Dice scores and reduced volume differences in tissue segmentation.
Magnetic resonance (MR) images from multiple sources often show differences in image contrast related to acquisition settings or the used scanner type. For long-term studies, longitudinal comparability is essential but can be impaired by these contrast differences, leading to biased results when using automated evaluation tools. This study presents a diffusion model-based approach for contrast harmonization. We use a data set consisting of scans of 18 Multiple Sclerosis patients and 22 healthy controls. Each subject was scanned in two MR scanners of different magnetic field strengths (1.5 T and 3 T), resulting in a paired data set that shows scanner-inherent differences. We map images from the source contrast to the target contrast for both directions, from 3 T to 1.5 T and from 1.5 T to 3 T. As we only want to change the contrast, not the anatomical information, our method uses the original image to guide the image-to-image translation process by adding structural information. The aim is that the mapped scans display increased comparability with scans of the target contrast for downstream tasks. We evaluate this method for the task of segmentation of cerebrospinal fluid, grey matter and white matter. Our method achieves good and consistent results for both directions of the mapping.
Motivation & Objective
- To address longitudinal comparability issues in multi-scanner MRI studies caused by scanner-induced contrast differences.
- To develop a method that harmonizes image contrast without altering anatomical structure, enabling reliable downstream analysis.
- To evaluate the effectiveness of diffusion models for image-to-image translation in medical imaging, particularly for contrast harmonization.
- To compare the performance of diffusion models against GAN-based approaches in preserving segmentation accuracy and spatial fidelity.
Proposed method
- A denoising diffusion probabilistic model (DDPM) is adapted for image-to-image translation between paired 1.5T and 3T MR scans.
- The model uses the source image as a conditional input to guide the translation, ensuring anatomical structure is preserved while only adjusting contrast.
- 2D slices are processed individually and then stacked into 3D volumes to reduce memory usage and avoid stripe artifacts.
- The method is trained on paired data from 18 MS patients and 22 healthy controls, with scans acquired at both 1.5T and 3T field strengths.
- Image translation is performed in both directions: from 1.5T to 3T and from 3T to 1.5T, enabling bidirectional harmonization.
- Segmentation performance is evaluated using FAST for CSF, GM, and WM, with metrics including Dice score, Hausdorff distance, and volume difference.
Experimental results
Research questions
- RQ1Can a diffusion model effectively harmonize MR image contrast between 1.5T and 3T scanners while preserving anatomical structure?
- RQ2How does the performance of the proposed diffusion model compare to a GAN-based baseline in terms of segmentation accuracy and spatial consistency?
- RQ3Does contrast harmonization via diffusion models reduce volume differences in tissue segmentation between scans of different field strengths?
- RQ4Can the method maintain high-quality segmentation outputs with minimal distortion in spatial boundaries, as measured by Hausdorff distance?
- RQ5Is the method robust across both directions of translation (1.5T→3T and 3T→1.5T), especially in the absence of adversarial training?
Key findings
- The proposed diffusion model achieves better Hausdorff distance scores than both the original images and the GAN-based method across all tissue classes (CSF, GM, WM) for both translation directions.
- For 1.5T-to-3T mapping, the diffusion model improves Dice scores for GM and WM compared to the original images, with a Dice score of 0.88 for WM and 0.88 for GM.
- The model reduces volume differences between segmented tissues in transformed images and ground truth (3T scans) more effectively than the GAN baseline, especially in the 1.5T-to-3T direction.
- The method maintains anatomical fidelity, as evidenced by the absence of stripe artifacts when stacking 2D slices into 3D volumes.
- The diffusion model outperforms the GAN-based method in terms of Hausdorff distance and segmentation consistency, despite a longer sampling time.
- The model shows strong generalization, achieving consistent performance in both directions of translation, with the best results observed in the 1.5T-to-3T mapping.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.