Skip to main content
QUICK REVIEW

[Paper Review] Feeder Topology Identification.

Raffi Sevlian, Ram Rajagopal|arXiv (Cornell University)|Mar 24, 2015
Optimal Power Flow DistributionEngineering12 references14 citations
TL;DR

This paper proposes a spanning tree identification method for residential distribution feeders using sparse power flow and load measurements to enable accurate feeder topology recognition. It establishes that sensor placement alone determines identifiability in the deterministic case and introduces a locally optimal sensor placement algorithm for noisy load forecasts.

ABSTRACT

Advanced control of distributed energy resources at the consumer level requires full situational awareness of the the distribution system. One important problem is that of feeder topology identification, due to changing switch configurations, given a sparse number of measurements. We formulate the problem for residential feeders as a spanning tree identification problem over a general graph. Given a set of power flow measurements and load pseudo measurements, we show that the underlying graph structure is crucial in defining identifiability of the correct spanning tree on the graph. First we solve the deterministic case of known true loads and measured power flow. We show that the placement of sensors on the network alone determine whether the set of spanning trees can be correctly identified. In the stochastic case where loads are in the form of noisy forecasts, we present a locally optimal sensor placement algorithm.

Motivation & Objective

  • To enable full situational awareness in distribution systems by identifying the correct feeder topology from sparse measurements.
  • To address the challenge of topology identification under dynamic switch configurations and limited measurement availability.
  • To determine the conditions under which the true spanning tree can be uniquely identified from power flow and load measurements.
  • To develop a sensor placement strategy that maximizes identifiability in the presence of noisy load forecasts.
  • To formalize the problem as a spanning tree identification task over a general graph structure.

Proposed method

  • Formulates feeder topology identification as a spanning tree identification problem on a general graph representing the distribution network.
  • Uses known true loads and measured power flows to solve the deterministic case, where identifiability depends solely on sensor placement.
  • Applies a graph-theoretic approach to analyze which spanning trees are distinguishable based on the measurement set.
  • Introduces a locally optimal sensor placement algorithm for the stochastic case with noisy load forecasts.
  • Leverages power flow measurements and pseudo measurements of load to infer network structure without requiring full observability.
  • Employs a mathematical framework to assess identifiability based on the network's graph structure and sensor configuration.

Experimental results

Research questions

  • RQ1Under what conditions can the true feeder topology be uniquely identified from a sparse set of power flow and load measurements?
  • RQ2How does sensor placement affect the identifiability of the correct spanning tree in a distribution network?
  • RQ3What is the impact of measurement noise on topology identification, and how can sensor placement mitigate this?
  • RQ4Can a locally optimal sensor placement strategy be derived for noisy load forecasts to maximize identifiability?
  • RQ5How does the underlying graph structure influence the feasibility of topology identification?

Key findings

  • The identifiability of the correct spanning tree is determined exclusively by sensor placement in the deterministic case with known true loads.
  • A unique solution exists only if the measurement set provides sufficient information to distinguish the true spanning tree from all other possible trees.
  • The proposed locally optimal sensor placement algorithm improves identifiability in the presence of noisy load forecasts.
  • The graph structure plays a critical role in defining whether the topology can be identified, regardless of measurement quantity.
  • The method enables topology identification without requiring full network observability, relying only on sparse measurements and load pseudo measurements.
  • The framework provides a foundation for real-time feeder topology monitoring in distribution systems with limited sensing.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.