Skip to main content
QUICK REVIEW

[Paper Review] Multimode optical fiber based spectrometers

Brandon Redding, Sébastien M. Popoff|arXiv (Cornell University)|Feb 19, 2013
Advanced Fiber Optic SensorsEngineering21 references95 citations
TL;DR

This paper proposes a compact, low-cost spectrometer using standard multimode optical fibers by leveraging wavelength-dependent speckle patterns from mode interference. By calibrating the fiber with a transmission matrix and applying a robust reconstruction algorithm, the system achieves high spectral resolution—resolving 8 pm line separation in a 20 m fiber and measuring broadband supercontinuum spectra in a 2 cm fiber—while mitigating noise and bandwidth limits via polarization diversity imaging.

ABSTRACT

A standard multimode optical fiber can be used as a general purpose spectrometer after calibrating the wavelength dependent speckle patterns produced by interference between the guided modes of the fiber. A transmission matrix was used to store the calibration data and a robust algorithm was developed to reconstruct an arbitrary input spectrum in the presence of experimental noise. We demonstrate that a 20 meter long fiber can resolve two laser lines separated by only 8 pm. At the other extreme, we show that a 2 centimeter long fiber can measure a broadband continuous spectrum generated from a supercontinuum source. We investigate the effect of the fiber geometry on the spectral resolution and bandwidth, and also discuss the additional limitation on the bandwidth imposed by speckle contrast reduction when measuring dense spectra. Finally, we demonstrate a method to reduce the spectrum reconstruction error and increase the bandwidth by separately imaging the speckle patterns of orthogonal polarizations. The multimode fiber spectrometer is compact, lightweight, low cost, and provides high resolution with low loss.

Motivation & Objective

  • To develop a low-cost, compact, and high-resolution spectrometer using standard multimode optical fibers.
  • To overcome the challenge of reconstructing input spectra from complex speckle patterns caused by mode interference in multimode fibers.
  • To improve spectral reconstruction accuracy and bandwidth by exploiting polarization diversity in speckle pattern imaging.
  • To characterize the trade-offs between fiber length, spectral resolution, and bandwidth in multimode fiber spectrometry.
  • To demonstrate practical feasibility across a wide dynamic range, from narrow-linewidth lasers to supercontinuum sources.

Proposed method

  • Calibration of the multimode fiber using a transmission matrix to map input wavelengths to output speckle patterns.
  • Application of a robust inverse algorithm to reconstruct input spectra from measured speckle patterns under experimental noise.
  • Use of a 20 m fiber for high-resolution measurement of closely spaced laser lines (8 pm separation).
  • Use of a 2 cm fiber to measure continuous broadband spectra from a supercontinuum source.
  • Implementation of orthogonal polarization imaging to reduce speckle contrast and increase effective measurement bandwidth.
  • Systematic analysis of spectral resolution and bandwidth dependence on fiber geometry and speckle characteristics.

Experimental results

Research questions

  • RQ1Can a standard multimode optical fiber be effectively repurposed as a high-resolution spectrometer through calibration of its wavelength-dependent speckle patterns?
  • RQ2How does fiber length affect spectral resolution and measurement bandwidth in multimode fiber spectrometry?
  • RQ3What is the impact of speckle contrast reduction on the effective spectral bandwidth when measuring dense or continuous spectra?
  • RQ4Can polarization diversity imaging improve spectral reconstruction accuracy and extend the usable bandwidth?
  • RQ5What are the practical limits of spectral resolution and dynamic range in a fiber-based spectrometer system?

Key findings

  • A 20-meter-long multimode fiber spectrometer successfully resolved two laser lines separated by only 8 pm, demonstrating high spectral resolution.
  • A 2-centimeter-long fiber was able to measure a continuous broadband spectrum from a supercontinuum source, showing suitability for wideband applications.
  • The system achieved high spectral resolution with low loss, making it suitable for compact, lightweight, and low-cost optical sensing.
  • Polarization diversity imaging reduced spectrum reconstruction error and increased the effective bandwidth by mitigating speckle contrast limitations.
  • Spectral resolution and bandwidth were found to be strongly dependent on fiber length and mode structure, with trade-offs between resolution and dynamic range.
  • The transmission matrix calibration method enabled robust reconstruction of arbitrary input spectra even in the presence of experimental noise.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.