[Paper Review] Novel Multi-pixel Silicon Photon Detectors and Applications in T2K

Dmitriy Beznosko|ArXiv.org|Oct 23, 2009
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy5 references12 citations
TL;DR

This paper presents the successful deployment and characterization of multi-pixel silicon photon detectors (MPPCs) in the T2K neutrino experiment's P0D sub-detector, demonstrating their reliability and stability in strong magnetic fields. The MPPCs, operating in Geiger mode with passive quenching, showed consistent gain, low dark noise, and stable photon detection efficiency, enabling high-performance light readout from scintillating bars with an average response of ~20 PE/MeV.

ABSTRACT

Nowadays, numerous fields such as High Energy Physics (HEP), medical imaging devices, portable radiation detectors etc., require a robust, miniature, reliable and readily available photon detector that is stable in a variety of environments, such as the presence of strong magnetic fields. The recently available $\sim$1mm$^{ extrm{2}}$ active area Multi-pixel Photon Counter (MPPC) sensors, produced by Hamamatsu Photonics, have been found to be reliable and an attractive choice for the HEP applications. The following sensor characteristics have been thoroughly tested by T2K collaboration: gain, dark noise, detection efficiency, reliability. These appear to be stable; in addition, the characteristic spread between numerous devices was assessed. Sensors with larger area are being developed for imaging and direct-to-scintillator coupling purposes.

Motivation & Objective

  • To evaluate the performance of novel 1mm² MPPC sensors in high-energy physics applications under strong magnetic fields.
  • To replace conventional PMTs, which suffer from magnetic field degradation, with a compact, robust, and cost-effective alternative.
  • To validate MPPC operation in the T2K ND280 off-axis detector, particularly in the P0D sub-detector for π⁰ detection.
  • To assess long-term stability and uniformity across ~11,000 MPPC sensors deployed in a real-world HEP experiment.
  • To explore broader applications of MPPCs in medical imaging, radiation detection, and security systems.

Proposed method

  • MPPCs were tested in a 0.2T magnetic field environment using calibrated light sources and radioactive sources to assess performance under real detector conditions.
  • Key parameters such as gain, dark noise, photon detection efficiency (PDE), and afterpulsing were measured as functions of bias voltage and temperature.
  • A 100x transimpedance amplifier was used to measure single photoelectron (PE) pulse amplitudes, enabling precise gain and PDE calibration.
  • The MPPC output was analyzed via ADC spectra and discriminator thresholds to quantify cross-talk and dark noise rates.
  • Sensors were characterized before, during, and after installation and shipping to Japan, including cosmic ray muon detection for in-situ validation.
  • Comparative testing was performed with other MPPC models and manufacturers, including irradiation (1 MRad) and 9T magnetic field exposure.

Experimental results

Research questions

  • RQ1Can MPPCs maintain stable gain, low dark noise, and consistent PDE in strong magnetic fields typical of HEP experiments?
  • RQ2How does MPPC performance—particularly gain, PDE, and dark noise—vary with bias voltage and temperature in a real detector environment?
  • RQ3What is the uniformity and reliability of MPPC sensors across a large-scale deployment of ~11,000 units in a high-precision physics detector?
  • RQ4To what extent do cross-talk and afterpulsing affect signal linearity and resolution in MPPC-based light detection systems?
  • RQ5Can MPPCs replace traditional PMTs in high-precision neutrino detectors like T2K’s P0D, especially in terms of long-term stability and low failure rate?

Key findings

  • MPPCs exhibited stable gain and PDE across a range of bias voltages and temperatures, with a temperature coefficient of breakdown voltage of 50 mV/°C.
  • Dark noise remained low and predictable, with a spread in operating voltage across ~11,000 sensors indicating high uniformity and low variation.
  • The average photoelectron (PE) output per MeV of deposited energy in scintillating bars was measured at ~20 PE/MeV, confirming high light collection efficiency.
  • Cross-talk and afterpulsing were observed to increase apparent PDE, but their effects were quantified and found to be manageable within the dynamic range of the system.
  • The MPPC demonstrated reliable performance in 0.2T magnetic field, outperforming conventional PMTs that showed strong angular dependence and crosstalk.
  • Post-deployment testing confirmed low failure rate, with only 14 sensors initially defective and four replaced later, indicating strong long-term stability.