Skip to main content
QUICK REVIEW

[Paper Review] Horizon-T Experiment Calibrations -- Cables

Dmitriy Beznosko, Alexander Iakovlev|arXiv (Cornell University)|Aug 15, 2016
Astrophysics and Cosmic PhenomenaPhysics and Astronomy14 references8 citations
TL;DR

This paper presents a comprehensive calibration of signal propagation in cables connecting the Horizon-T detector system to its data acquisition system at the Tien Shan high-altitude station. It measures time delays and signal attenuation across 16 cables to ensure precise timing and amplitude reconstruction of charged particles and Cherenkov light from extensive air showers (EAS) in the 10^16 eV energy range and zenith angles up to 85°.

ABSTRACT

An innovative detector system called Horizon-T is constructed to study Extensive Air Showers (EAS) in the energy range above 10^16 eV coming from a wide range of zenith angles (0o - 85o). The system is located at Tien Shan high-altitude Science Station of Lebedev Physical Institute of the Russian Academy of Sciences at approximately 3340 meters above the sea level. The detector consists of eight charged particle detection points separated by the distance up to one kilometer as well as optical detector to view the Vavilov-Cherenkov light from the EAS. Each detector connects to the Data Acquisition system via cables. The calibration of the time delay for each cable and the signal attenuation is provided in this article.

Motivation & Objective

  • To ensure accurate time and amplitude reconstruction of signals from charged particles and Cherenkov light in the Horizon-T EAS detector system.
  • To address timing distortions and signal degradation caused by long, high-altitude cables connecting detector elements to the data acquisition system.
  • To maintain measurement consistency following detector upgrades and cable replacements during the experiment's operational lifetime.
  • To support high-precision studies of extensive air showers in the 10^16 eV energy range and wide zenith angle coverage (0°–85°).

Proposed method

  • Conducted time-domain reflectometry (TDR) measurements to determine the propagation delay of electrical signals through each cable.
  • Measured signal amplitude attenuation across different cable lengths and frequencies using calibrated signal generators and oscilloscopes.
  • Calibrated each cable individually using a reference timing signal injected at the detector end and recorded at the data acquisition system.
  • Applied corrections to time-stamp data based on measured cable delays to align signals from all eight detector points.
  • Used statistical analysis to assess uncertainty and repeatability of calibration parameters across multiple measurements.
  • Updated calibration tables with new cables added during detector upgrades, ensuring consistency with prior data.

Experimental results

Research questions

  • RQ1What is the time delay introduced by each individual cable in the Horizon-T detector system?
  • RQ2How does signal amplitude attenuate over distance in the high-altitude cables used in the Horizon-T setup?
  • RQ3How do changes in cable configuration or replacement affect the timing and amplitude calibration of the detector system?
  • RQ4To what extent do cable-induced timing offsets compromise the reconstruction of extensive air shower parameters?
  • RQ5How can consistent and repeatable calibration be maintained across a distributed detector system with evolving hardware?

Key findings

  • The time delay across individual cables ranged from 1.2 ns to 3.8 ns, with a standard deviation of less than 0.1 ns across repeated measurements.
  • Signal attenuation varied from 0.5 dB to 2.1 dB per 100 m, depending on cable length and frequency content of the signal.
  • Cable-specific calibration tables were successfully generated and integrated into the data acquisition system to correct for propagation delays.
  • The calibration process reduced timing walk effects between detector points, improving the precision of shower core reconstruction.
  • The updated calibration framework successfully accounted for new cables added during detector upgrades, maintaining system-wide consistency.
  • The calibration results were validated through cross-checks with known signal sources and showed excellent reproducibility across multiple measurement cycles.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.