[Paper Review] Ohm's law revision
This paper revises Ohm's law by identifying a thermal correction to resistance measurements due to the Peltier effect at current-carrying contacts. The correction arises from temperature differences at contacts and appears as a linear term in current, persisting even at zero current; however, it vanishes above a critical frequency due to thermal inertia, necessitating correction in precise resistance measurements.
The standard ohmic measurements by means of two extra leads contain an additional thermal correction to resistance. The current results in heating(cooling) at first(second) sample contact due to Peltier effect. The contacts temperatures are different. The measured voltage is the sum of the ohmic voltage swing and Peltier effect induced thermopower which is linear on current. As a result, the thermal correction to resistance measured exists at $I o 0$. The correction should be in comparison with ohmic resistance. Above some critical frequency dependent on thermal inertial effects the thermal correction disappears.
Motivation & Objective
- To identify and quantify an overlooked thermal correction in standard two-lead ohmic resistance measurements.
- To explain the origin of a non-ohmic voltage contribution caused by Peltier effects at current-carrying contacts.
- To determine the conditions under which this thermal correction vanishes due to thermal inertia.
- To clarify that this correction persists at zero current and must be distinguished from true ohmic resistance.
Proposed method
- Modeling the contact interface as a Peltier junction where current flow induces heating or cooling depending on current direction.
- Deriving the thermopower contribution to the measured voltage as linear in current, arising from temperature differences at the contacts.
- Analyzing the system's thermal response to time-varying current, introducing a frequency-dependent thermal time constant.
- Using thermal inertia to determine a critical frequency above which the thermal correction becomes negligible.
- Comparing the magnitude of the Peltier-induced correction to the actual ohmic resistance to assess its significance.
- Applying the model to standard two-lead resistance measurements to quantify the deviation from ideal Ohm's law.
Experimental results
Research questions
- RQ1What causes a non-ohmic voltage contribution in standard two-lead resistance measurements at non-zero current?
- RQ2How does the Peltier effect at contact interfaces lead to a thermal correction in resistance measurements?
- RQ3Why does this correction persist even when the current is zero?
- RQ4At what frequency does the thermal correction vanish due to thermal inertia?
- RQ5How does the magnitude of the thermal correction compare to the actual ohmic resistance?
Key findings
- A thermal correction to resistance measurements arises from the Peltier effect at current-carrying contacts, causing temperature differences between contact points.
- This correction appears as a linear term in current and persists even at zero current, violating ideal Ohm's law.
- The correction is proportional to the Peltier coefficient and the current, and is detectable in standard two-lead measurements.
- The correction vanishes above a critical frequency that depends on the thermal inertia of the system.
- The magnitude of the correction must be compared with the ohmic resistance to assess its significance in precision measurements.
- The results imply that standard two-lead resistance measurements require correction for Peltier-induced thermopower in high-precision applications.