Skip to main content
QUICK REVIEW

[Paper Review] Placement and Implementation of Grid-Forming and Grid-Following Virtual Inertia

Bala Kameshwar Poolla, Dominic Groß|arXiv (Cornell University)|Jul 5, 2018
Microgrid Control and OptimizationEngineering3 citations
TL;DR

This paper proposes optimizing the placement and parameters of grid-forming and grid-following virtual inertia (VI) devices to enhance frequency stability in low-inertia power systems. By formulating an optimization problem based on a high-fidelity model of the South-East Australian grid, the study demonstrates that coordinated VI deployment significantly reduces frequency excursions and improves system resilience.

ABSTRACT

The electric power system is witnessing a shift in the technology of generation. Conventional thermal generation based on synchronous machines is gradually being replaced by power electronics interfaced renewable generation. This new mode of generation, however, lacks the natural inertia and governor damping which are quintessential features of synchronous machines. The loss of these features results in increasing frequency excursions and, ultimately, system instability. Among the numerous studies on mitigating these undesirable effects, the main approach involves virtual inertia emulation to mimic the behavior of synchronous machines. In this work, explicit models of grid-following and grid-forming virtual inertia (VI) devices are developed for inertia emulation in low-inertia systems. An optimization problem is formulated to optimize the parameters and location of these devices in a power system to increase its resilience. Finally, a case study based on a high-fidelity model of the South-East Australian system is used to illustrate the effectiveness of such devices.

Motivation & Objective

  • Address the growing instability in power systems due to the replacement of synchronous machines with inverter-based renewable generation.
  • Mitigate the loss of natural inertia and governor damping by emulating these dynamic characteristics through virtual inertia (VI) devices.
  • Develop explicit models of both grid-following and grid-forming VI devices for accurate inertia emulation in low-inertia systems.
  • Formulate and solve an optimization problem to determine optimal VI device parameters and locations for maximum system resilience.
  • Validate the effectiveness of the proposed approach using a high-fidelity model of the South-East Australian power system.

Proposed method

  • Develop explicit dynamic models for both grid-following and grid-forming virtual inertia devices to accurately represent their behavior in low-inertia systems.
  • Formulate an optimization problem that jointly determines the optimal placement and parameter tuning of VI devices to maximize system resilience.
  • Use a high-fidelity dynamic model of the South-East Australian power system as the test case for evaluating the proposed method.
  • Integrate the VI devices into the system model with precise control strategies to emulate the inertial response of synchronous machines.
  • Apply time-domain simulations to assess frequency response under various contingency scenarios, evaluating the performance of the optimized VI configuration.

Experimental results

Research questions

  • RQ1How can virtual inertia be effectively emulated using both grid-forming and grid-following control strategies in low-inertia power systems?
  • RQ2What is the optimal placement and parameter setting of virtual inertia devices to maximize system resilience and minimize frequency deviations?
  • RQ3How do grid-forming and grid-following VI devices compare in their ability to stabilize frequency under large disturbances?
  • RQ4To what extent can coordinated VI deployment reduce frequency excursion magnitudes in a real-world, high-fidelity power system model?

Key findings

  • The integration of optimized virtual inertia devices significantly reduces frequency excursion magnitudes in the South-East Australian power system under disturbance conditions.
  • Grid-forming virtual inertia provides stronger primary frequency support and improves system strength, especially during large disturbances.
  • Grid-following virtual inertia enhances dynamic response and supports voltage support, particularly in weak grid conditions.
  • The joint optimization of device parameters and locations leads to a measurable improvement in system resilience compared to conventional or unoptimized VI deployment.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.