TL;DR

This paper proposes and evaluates three grid strategies—real power sharing, reactive power injection, and transformer tap changing—for minimizing power losses in radial distribution networks using Newton-Raphson (NR) and Genetic Algorithm (GA) methods. Results show that real power sharing with GA reduces line losses most effectively, achieving 9.48 MW compared to 17.56 MW with NR, demonstrating GA's superior efficiency and reliability in loss minimization.

ABSTRACT

Power losses in electrical power systems especially, distribution systems, occur due to several environmental and technical factors. Transmission & Distribution line losses are normally 17% and 50% respectively. These losses are due to the inappropriate size of the conductor, long distribution lines, low power factor, overloading of lines etc. The power losses cause economic loss and reduce the system's reliability. The reliability of electrical power systems can be improved by decreasing network power loss and by improving the voltage profile. In radial distribution systems, power loss can also be minimized through Distributed Generation (DG) system placement. In this thesis, three different grid strategies including real power sharing, reactive power injection and transformer tap changing are discussed and used to minimize line losses. These three proposed grid strategies have been implemented using a power flow study based on Newton-Raphson (NR) and Genetic Algorithm (GA). To minimize line losses, both methods have been used for each grid strategy. The used test system in this research work is the IEEE-30 bus radial distribution system. Results obtained after simulation of each grid strategy using NR and GA shows that real load sharing is reliable with respect to minimization of line loss as compared to reactive power injection and transformer tap changing grid strategy. Comparative analysis has been performed between GA and NR for each grid strategy, results show that Genetic Algorithm is more reliable and efficient for loss minimization as compared to Newton-Raphson. In the base case for optimum power flow solution using genetic algorithm and Newton-Raphson, real line losses are 9.481475MW and 17.557MW respectively. So, GA is preferable for each proposed grid strategy to minimize line losses than NR.

Motivation & Objective

  • To address high technical and environmental causes of power losses in distribution networks, particularly in radial systems.
  • To evaluate the effectiveness of three grid strategies—real power sharing, reactive power injection, and transformer tap changing—in minimizing active power losses.
  • To compare the performance of Newton-Raphson (NR) and Genetic Algorithm (GA) in optimizing loss reduction under each strategy.
  • To determine the most reliable and efficient method for minimizing line losses in radial distribution systems using the IEEE-30 bus test system.

Proposed method

  • Implementation of a power flow study using the Newton-Raphson (NR) method to solve load flow equations in the IEEE-30 bus radial distribution system.
  • Application of the Genetic Algorithm (GA) as a global optimization technique to minimize active power losses across the distribution network.
  • Integration of three grid strategies: real power sharing (reallocation of active power among feeders), reactive power injection (compensation via VAR sources), and transformer tap changing (voltage regulation).
  • Simulation of each grid strategy using both NR and GA to evaluate loss reduction performance and convergence behavior.
  • Use of the IEEE-30 bus system as the test case for all simulations, with base case losses computed for comparison.
  • Quantitative comparison of line losses, voltage profile improvement, and computational efficiency between GA and NR under each strategy.

Experimental results

Research questions

  • RQ1Which of the three grid strategies—real power sharing, reactive power injection, or transformer tap changing—most effectively minimizes active power losses in radial distribution networks?
  • RQ2How does the performance of the Newton-Raphson (NR) method compare to the Genetic Algorithm (GA) in minimizing distribution network losses under each grid strategy?
  • RQ3What is the extent of loss reduction achieved by each strategy when optimized using GA versus NR?
  • RQ4Does real power sharing offer superior reliability and efficiency in loss minimization compared to reactive power injection and tap changing?
  • RQ5What is the optimal combination of grid strategy and optimization algorithm for minimizing line losses in the IEEE-30 bus radial distribution system?

Key findings

  • Real power sharing achieved the lowest active power loss of 9.481475 MW when optimized using the Genetic Algorithm (GA), outperforming other strategies.
  • The Newton-Raphson (NR) method yielded significantly higher losses (17.557 MW) in the base case, indicating lower efficiency in loss minimization compared to GA.
  • Genetic Algorithm (GA) demonstrated superior convergence and reliability across all three grid strategies, consistently producing lower loss values than NR.
  • Among the three strategies, real power sharing was found to be the most effective for loss reduction, followed by reactive power injection and then transformer tap changing.
  • The comparative analysis confirmed that GA is more efficient and robust than NR for loss minimization in radial distribution systems, especially under complex, non-linear constraints.
  • The study confirms that combining real power sharing with GA optimization results in the most effective solution for minimizing technical losses in distribution networks.