Skip to main content
QUICK REVIEW

[Paper Review] Precision of silicon oxynitride refractive-index profile retrieval using optical characterization

Vít Kanclíř, J. Václavík|arXiv (Cornell University)|Dec 8, 2020
Metal and Thin Film MechanicsEngineering23 references7 citations
TL;DR

This study investigates the precision of refractive-index profile retrieval in silicon oxynitride (SiOxNy) thin films deposited via dual ion beam sputtering using combined reflectance, transmittance, and ellipsometry measurements at multiple angles. Despite seemingly high precision in parameter scanning, the study reveals that a broad range of gradient profiles—with refractive index varying by up to ±0.02 from the mean value—can equally well fit experimental data, indicating fundamental ambiguity in profile reconstruction.

ABSTRACT

Layers with gradient refractive-index profile are an attractive alternative to conventional homogeneous stack coatings. However, the optical characterization and monitoring of the graded refractive-index profile is a complex issue, which has been typically solved by using a simplified model of mixed materials. Although this approach provides a solution to the problem, the precision, which can be expected from optical characterization of the refractive index gradient, remains unclear. In this work, we study optical characterization of SiO_xN_y layers deposited via reactive dual ion beam sputtering. To characterize the deposited layers, we use several methods including reflectance, and transmittance spectra at a broad range of incident angles, together with spectral ellipsometry. All the data were simultaneously fitted with a general profile of refractive index. The expected profile used in our fit was based on characterization of SiO_xN_y layers with a varying stoichiometry. By altering of the profile, we discussed sensitivity of such alternation on fit quality and we studied ambiguity of merit-function minimization. We demonstrate that while the scanning of particular parameters of the profile can be seemingly very precise, we obtain a very good agreement between the experimental data and model for a broad range of gradient shapes, where the refractive-index value on major part of the profile can differ as much as 0.02 from the mean value.

Motivation & Objective

  • To assess the precision of optical characterization in retrieving gradient refractive-index profiles in SiOxNy thin films.
  • To investigate the ambiguity and sensitivity of merit-function minimization in profile reconstruction using experimental data.
  • To evaluate whether systematic parameter variation reliably identifies the true refractive-index profile or if multiple profiles yield equally good fits.
  • To determine the practical limits of precision in optical characterization of graded-index thin films.

Proposed method

  • Deposited SiOxNy films via reactive dual ion beam sputtering with controlled stoichiometry gradients.
  • Measured reflectance, transmittance, and ellipsometry across a broad range of incident angles.
  • Used a 4th-order polynomial to model the refractive-index profile and simultaneously fit all optical data.
  • Performed systematic and random variations of the refractive-index profile to assess sensitivity and fit quality.
  • Compared fit quality (merit function) between systematically optimized profiles and randomly perturbed profiles.
  • Evaluated the spread of retrieved refractive-index values across different z-positions to quantify uncertainty.

Experimental results

Research questions

  • RQ1What is the actual precision achievable in reconstructing the refractive-index profile of a gradient SiOxNy film using standard optical characterization?
  • RQ2How sensitive is the fit quality to small, random variations in the refractive-index profile?
  • RQ3Can multiple distinct refractive-index profiles produce equally good agreement with experimental data?
  • RQ4Why does systematic optimization fail to converge to the central region of the best-fitting profiles observed in random simulations?
  • RQ5To what extent does the ambiguity in profile reconstruction limit the reliability of optical characterization?

Key findings

  • A broad range of refractive-index profiles—with variations of up to ±0.02 from the mean value—can achieve equally good agreement with experimental data, indicating significant ambiguity in profile retrieval.
  • The systematic optimization process, despite showing a sharp minimum in the merit function, does not converge to the central region of the best-fitting profiles identified through random perturbations.
  • Randomly perturbed profiles with merit functions below the systematically optimized value (0.733) were found, demonstrating that the systematic approach may not locate the global minimum.
  • The spread in refractive-index values across the profile is smallest at mid-layer positions (e.g., z = 200 nm and z = 225 nm), where values range from 1.559 to 1.577 and 1.537 to 1.555, respectively.
  • Edge regions (e.g., z = 0 nm) show the largest spread (1.969 to 2.043), likely due to fitting artifacts from polynomial approximation and data point sensitivity.
  • Small changes in key profile parameters—such as a +0.02 increase in refractive index at a specific oxygen flow rate—can drastically alter the optimized profile, highlighting high sensitivity and non-uniqueness of solutions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.