This paper presents a compact, fiber-tip endoscopic quantitative phase imaging system using a chromatic silicon nitride metalens that enables single-shot phase retrieval via spectral multiplexing across multiple defocus planes. The metalens achieves 0.1λ phase sensitivity over a 280° field of view without external filters or mechanical scanning, overcoming key limitations in conventional QPI systems.
Quantitative phase imaging (QPI) recovers the exact wavefront of light from the intensity measured by a camera. Topographical maps of translucent microscopic bodies can be extracted from these quantified phase shifts. We demonstrate quantitative phase imaging at the tip of an optical fiber endoscope with a chromatic silicon nitride metalens. Our method leverages spectral multiplexing to recover phase from multiple defocus planes in a single capture. The half millimeter wide metalens shows phase imaging capability with a 280 field of view and 0.1λ sensitivity in experiments with an endoscopic fiber bundle. Since the spectral functionality is encoded directly in the imaging lens, no additional filters are needed. Key limitations in the scaling of a phase imaging system, such as multiple acquisition, interferometric alignment or mechanical scanning are completely mitigated in the proposed scheme
Motivation & Objective
- To develop a miniaturized, endoscopic quantitative phase imaging system compatible with fiber-optic platforms.
- To overcome traditional limitations in QPI, such as multiple acquisitions, interferometric alignment, and mechanical scanning.
- To enable high-sensitivity phase imaging using a single optical component with integrated spectral multiplexing functionality.
- To demonstrate phase imaging performance at the tip of an optical fiber using a compact metalens.
Proposed method
- A chromatic silicon nitride metalens is fabricated at the tip of an optical fiber to simultaneously focus different wavelengths to distinct axial positions.
- Spectral multiplexing is employed to encode phase information across multiple defocus planes in a single camera exposure.
- The metalens's wavelength-dependent phase profile allows for direct recovery of the wavefront from intensity measurements without additional filters.
- Phase retrieval is achieved by solving an inverse problem using the known spectral response of the metalens and intensity data from a single capture.
- The system leverages the metalens's inherent chromatic dispersion to encode defocus diversity, enabling quantitative phase reconstruction.
Experimental results
Research questions
- RQ1Can a metalens integrated at the tip of an optical fiber enable single-shot quantitative phase imaging without external components?
- RQ2How does the spectral multiplexing capability of a chromatic metalens support phase retrieval across multiple defocus planes?
- RQ3What is the achievable phase sensitivity and field of view of a fiber-integrated metalens for endoscopic QPI?
- RQ4To what extent can the need for mechanical scanning or interferometric alignment be eliminated using a metalens-based approach?
- RQ5Can a compact, all-in-one lens design achieve performance comparable to conventional QPI systems?
Key findings
- The metalens achieves a phase sensitivity of 0.1λ, demonstrating high-precision phase measurement capability.
- The system provides a 280° field of view, enabling wide-field quantitative phase imaging at the fiber tip.
- Single-shot phase retrieval is achieved without additional filters, mechanical scanning, or interferometric alignment.
- The metalens's chromatic dispersion is harnessed to encode defocus diversity, enabling robust phase reconstruction from one intensity image.
- The method is fully integrated into the lens, eliminating the need for external optical components.