[Paper Review] Radar Cross Section Measurement within Reverberation Chamber: Stirrer position issues
This paper evaluates radar cross section (RCS) measurement of metallic objects using a reverberation chamber (RC) by isolating the ballistic wave from the target's backscattered response. It demonstrates good agreement with anechoic chamber measurements but identifies stirrer positioning as a critical factor affecting RCS accuracy, highlighting its impact on field uniformity and measurement repeatability.
This paper presents the evaluation of the Radar Cross Section (RCS) of a metallic object by measurements accomplished within the diffuse-field environment produced by a Reverberation Chamber (RC). The method is based on the extraction of the ballistic wave between the antenna and the target that is mixed with the backscattering response of the RC. A good agreement is obtained when compared with classical RCS measurement inside an anechoic chamber. This communication also highlights the potential stirrer positioning issues and their impact on the retrieved RCS accuracy.
Motivation & Objective
- To evaluate the feasibility of measuring radar cross section (RCS) of metallic objects using a reverberation chamber (RC) as an alternative to anechoic chambers.
- To investigate the influence of stirrer positioning on the accuracy and repeatability of RCS measurements in RC environments.
- To compare RC-based RCS measurements with classical anechoic chamber measurements for validation.
- To identify and analyze field irregularities caused by improper stirrer placement in RC setups.
Proposed method
- The method isolates the ballistic wave component between the transmitting antenna and the target from the total backscattered response in the RC.
- It employs signal processing techniques to separate the direct path wave from the reverberant field response.
- Measurements are performed with multiple stirrer positions to assess field distribution and coherence.
- The RCS is computed from the amplitude and phase of the extracted ballistic wave component.
- The setup uses a calibrated transmitter and receiver system within a standard RC with rotating stirrers.
- Results are validated by comparison with reference RCS measurements conducted in an anechoic chamber.
Experimental results
Research questions
- RQ1How accurately can RCS be measured in a reverberation chamber compared to conventional anechoic chamber methods?
- RQ2What is the impact of stirrer position on the uniformity and coherence of the diffuse field within the RC?
- RQ3How does stirrer positioning affect the extraction of the ballistic wave and subsequent RCS calculation?
- RQ4Can a reverberation chamber provide reliable RCS measurements when stirrer positions are suboptimal?
Key findings
- The RCS measurement method in the reverberation chamber shows good agreement with reference anechoic chamber measurements, validating its feasibility.
- Stirrer positioning significantly affects field uniformity, leading to measurable variations in the retrieved RCS values.
- Suboptimal stirrer positions introduce field inhomogeneities that distort the ballistic wave extraction process.
- The study identifies specific stirrer configurations that degrade measurement accuracy due to interference patterns and non-uniform field excitation.
Read this paper