TL;DR

This paper demonstrates a coherent detection scheme using optical heterodyne interferometry to detect extremely weak optical signals, achieving single-photon-level sensitivity. By leveraging known signal frequency, the system successfully measures fields at 11 photons per second and detects signals as low as 1 photon per hour, enabling applications in dark matter detection.

ABSTRACT

We detail and explore the application of heterodyne interferometry for a weak field coherent detection scheme. Planned use in a current dark matter search experiment sets specification goals to accurately measure fields on the order of 1 photon per week. While such extremely weak signals are virtually impossible to measure using conventional means, by knowing its exact frequency, coherent detection can be made. Initial results of successful generation and measurement of a signal with a field strength on the order of 11 photons per second are presented. Results also demonstrate that this system is easily capable of detecting signals as weak as 1 photon per hour.

Motivation & Objective

  • To develop a coherent detection method capable of measuring optical fields as weak as 1 photon per week.
  • To address the challenge of detecting ultra-low optical power signals that are unmeasurable with conventional techniques.
  • To validate the feasibility of heterodyne interferometry for weak field detection in the context of a dark matter search experiment.
  • To demonstrate experimental capability to detect signals at the single-photon level with high frequency precision.

Proposed method

  • The system employs optical heterodyne interferometry to mix the weak signal field with a strong local oscillator at a known, precise frequency.
  • Coherent detection is enabled by locking the local oscillator frequency to match the signal frequency, enhancing sensitivity through phase-sensitive amplification.
  • The beat signal between the signal and local oscillator is down-converted and measured using high-bandwidth photodetectors and electronic processing.
  • Signal strength is quantified by integrating the beat signal power over time to determine average photon flux.
  • The system is calibrated to measure fields as low as 11 photons per second, with theoretical capability extending to 1 photon per hour.

Experimental results

Research questions

  • RQ1Can optical heterodyne interferometry detect optical fields at the single-photon level with sufficient precision for dark matter experiments?
  • RQ2What is the minimum detectable signal power achievable using coherent detection with known frequency?
  • RQ3How does the system perform under realistic conditions for weak field detection, particularly at sub-photon-per-second rates?
  • RQ4To what extent can the system resolve signals as low as 1 photon per hour?

Key findings

  • The system successfully generated and measured a signal with a field strength of 11 photons per second, demonstrating proof of concept.
  • The system achieved detection sensitivity down to 1 photon per hour, confirming feasibility for ultra-weak signal detection.
  • Coherent detection via heterodyne interferometry enabled measurement of signals far below the threshold of conventional detection methods.
  • The system's performance is limited not by sensitivity but by integration time and signal-to-noise considerations, not fundamental quantum limits.