[Paper Review] SK-Unet: an Improved U-net Model with Selective Kernel for the Segmentation of Multi-sequence Cardiac MR
This paper proposes SK-Unet, an enhanced U-Net architecture integrating selective kernel (SK) modules and squeeze-and-excitation residual (SE-Res) units for multi-sequence cardiac MR image segmentation. By fusing cine, T2-weighted, and LGE CMRIs, the model improves feature representation in both channel and spatial dimensions, achieving mean Dice scores of 0.922 (LV), 0.827 (LVM), and 0.874 (RV) on the MS-CMRSeg 2019 dataset.
In the clinical environment, myocardial infarction (MI) as one com-mon cardiovascular disease is mainly evaluated based on the late gadolinium enhancement (LGE) cardiac magnetic resonance images (CMRIs). The auto-matic segmentations of left ventricle (LV), right ventricle (RV), and left ven-tricular myocardium (LVM) in the LGE CMRIs are desired for the aided diag-nosis in clinic. To accomplish this segmentation task, this paper proposes a modified U-net architecture by combining multi-sequence CMRIs, including the cine, LGE, and T2-weighted CMRIs. The cine and T2-weighted CMRIs are used to assist the segmentation in the LGE CMRIs. In this segmentation net-work, the squeeze-and-excitation residual (SE-Res) and selective kernel (SK) modules are inserted in the down-sampling and up-sampling stages, respective-ly. The SK module makes the obtained feature maps more informative in both spatial and channel-wise space, and attains more precise segmentation result. The utilized dataset is from the MICCAI challenge (MS-CMRSeg 2019), which is acquired from 45 patients including three CMR sequences. The cine and T2-weighted CMRIs acquired from 35 patients and the LGE CMRIs acquired from 5 patients are labeled. Our method achieves the mean dice score of 0.922 (LV), 0.827 (LVM), and 0.874 (RV) in the LGE CMRIs.
Motivation & Objective
- To improve automatic segmentation of left ventricle (LV), right ventricle (RV), and left ventricular myocardium (LVM) in late gadolinium enhancement (LGE) cardiac MR images.
- To leverage complementary information from multi-sequence CMRIs—specifically cine, T2-weighted, and LGE sequences—to enhance segmentation accuracy.
- To address the challenge of limited annotation in LGE CMRIs by using additional sequences as auxiliary supervision.
- To enhance feature representation in both spatial and channel dimensions through attention mechanisms in the U-Net architecture.
- To achieve state-of-the-art performance on the MS-CMRSeg 2019 benchmark for cardiac MR segmentation.
Proposed method
- The proposed SK-Unet integrates squeeze-and-excitation residual (SE-Res) modules in the down-sampling path to recalibrate channel-wise feature responses.
- Selective kernel (SK) modules are applied in the up-sampling path to adaptively aggregate multi-receptive field features for improved spatial representation.
- Multi-sequence CMRIs (cine, T2-weighted, and LGE) are concatenated as input to the network to exploit complementary anatomical and functional information.
- The network uses skip connections from encoder to decoder to preserve spatial details lost during downsampling.
- The model is trained end-to-end using a combination of cross-entropy and Dice loss to optimize segmentation performance.
- Feature maps are dynamically reweighted by the SK module based on their importance in both spatial and channel dimensions.
Experimental results
Research questions
- RQ1Can the integration of multi-sequence CMRIs (cine, T2-weighted, and LGE) improve segmentation accuracy of LV, RV, and LVM in LGE images?
- RQ2Does the selective kernel module enhance feature representation in both spatial and channel dimensions for better segmentation?
- RQ3Can the SE-Res module improve feature refinement in the encoder path for more robust feature learning?
- RQ4How does SK-Unet compare to standard U-Net and other attention-based architectures on the MS-CMRSeg 2019 dataset?
- RQ5To what extent can auxiliary sequences (cine and T2-weighted) compensate for limited annotations in LGE CMRIs?
Key findings
- The proposed SK-Unet achieved a mean Dice score of 0.922 for left ventricle (LV) segmentation on the LGE CMRIs.
- The model achieved a mean Dice score of 0.827 for left ventricular myocardium (LVM) segmentation, indicating strong performance on the challenging myocardial tissue.
- A mean Dice score of 0.874 was obtained for right ventricle (RV) segmentation, demonstrating robustness in the smaller and more irregularly shaped structure.
- The integration of multi-sequence CMRIs significantly improved segmentation performance compared to using LGE alone, due to enhanced anatomical context.
- The selective kernel module contributed to more informative feature maps by adaptively focusing on relevant spatial and channel features.
- The combination of SE-Res and SK modules led to improved feature representation, resulting in higher segmentation accuracy than baseline U-Net.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.