[Paper Review] Sparse Doppler Sensing.

Regev Cohen, Yonina C. Eldar|arXiv (Cornell University)|Oct 2, 2017
Advanced MRI Techniques and ApplicationsMedicine1 citations
TL;DR

This paper proposes a non-uniform slow-time transmission scheme using nested arrays to reduce Doppler pulse emissions in spectral Doppler ultrasound while enabling perfect spectrum reconstruction with minimal transmissions. It achieves high frame-rate duplex imaging by freeing up acquisition time for B-mode imaging, using two spectrum recovery methods: FFT-based and continuous off-grid recovery.

ABSTRACT

Spectral Doppler ultrasound imaging allows visualizing blood flow by estimating its velocity distribution over time. Duplex ultrasound is a modality in which an ultrasound system is used for displaying simultaneously both B-mode images and spectral Doppler data. In B-mode imaging short wide-band pulses are used to achieve sufficient spatial resolution in the images. In contrast, for Doppler imaging, narrow-band pulses are preferred in order to attain increased spectral resolution. Thus, the acquisition time must be shared between the two sequences. In this work, we propose a non-uniform slow-time transmission scheme for spectral Doppler, based on nested arrays, which reduces the number of pulses needed for accurate spectrum recovery. We derive the minimal number of Doppler emissions needed, using this approach, for perfect reconstruction of the blood spectrum in a noise-free environment. Next, we provide two spectrum recovery techniques which achieve this minimal number. The first method performs efficient recovery based on the fast Fourier transform. The second allows for continuous recovery of the Doppler frequencies, thus avoiding off-grid error leakage, at the expense of increased complexity. The performance of the techniques is evaluated using realistic Field II simulations as well as in vivo measurements, producing accurate spectrograms of the blood velocities using a significant reduced number of transmissions. The time gained, where no Doppler pulses are sent, can be used to enable the display of both blood velocities and high quality B-mode images at a high frame rate.

Motivation & Objective

  • Address the trade-off between B-mode and spectral Doppler imaging in duplex ultrasound by reducing Doppler pulse transmissions.
  • Minimize the number of Doppler emissions required for perfect spectrum reconstruction in a noise-free environment.
  • Enable high frame-rate imaging by freeing up time during acquisition that would otherwise be used for Doppler pulses.
  • Develop spectrum recovery techniques that achieve the theoretical minimum number of transmissions for accurate velocity estimation.
  • Evaluate performance using realistic Field II simulations and in vivo measurements to validate clinical feasibility.

Proposed method

  • Propose a non-uniform slow-time transmission scheme based on nested array geometry to achieve sparse sampling of the Doppler signal.
  • Derive the theoretical minimum number of Doppler emissions required for perfect spectrum reconstruction in noise-free conditions.
  • Implement an FFT-based spectrum recovery method that efficiently reconstructs the Doppler spectrum from the minimal number of non-uniform pulses.
  • Introduce a continuous recovery technique that avoids off-grid error leakage by modeling Doppler frequencies as continuous variables, improving accuracy at the cost of higher computational complexity.
  • Leverage the time saved from reduced Doppler transmissions to allocate more time to B-mode imaging, enabling high frame-rate simultaneous display.
  • Validate the approach using Field II simulations and in vivo ultrasound data to assess spectral accuracy and imaging performance.

Experimental results

Research questions

  • RQ1What is the minimal number of Doppler emissions required for perfect reconstruction of the blood velocity spectrum in a noise-free environment?
  • RQ2Can a non-uniform transmission scheme based on nested arrays achieve this minimal transmission count while preserving spectral resolution?
  • RQ3How do the proposed FFT-based and continuous recovery methods compare in terms of accuracy and computational complexity?
  • RQ4To what extent can the time saved from reduced Doppler transmissions improve B-mode imaging frame rate in duplex mode?
  • RQ5Can the proposed method maintain accurate spectrograms in realistic and in vivo ultrasound environments?

Key findings

  • The proposed non-uniform slow-time transmission scheme based on nested arrays achieves perfect Doppler spectrum reconstruction using the theoretically minimal number of pulses in a noise-free setting.
  • The FFT-based recovery method enables efficient spectrum reconstruction with the minimal number of transmissions, ensuring computational feasibility.
  • The continuous recovery technique avoids off-grid error leakage by modeling Doppler frequencies as continuous variables, improving spectral accuracy at the cost of increased complexity.
  • Field II simulations and in vivo measurements demonstrate accurate spectrograms of blood velocities using significantly fewer Doppler transmissions than conventional methods.
  • The time saved from reduced Doppler pulse emissions allows for high frame-rate B-mode imaging, enabling simultaneous high-quality B-mode and Doppler visualization.
  • The method enables high frame-rate duplex imaging by reallocating time previously used for Doppler pulses to B-mode acquisition, enhancing clinical imaging performance.