Skip to main content
QUICK REVIEW

[Paper Review] Stability of noisy quantum computing devices

Samudra Dasgupta, Travis S. Humble|arXiv (Cornell University)|May 20, 2021
Quantum Computing Algorithms and ArchitectureComputer Science33 references19 citations
TL;DR

This paper proposes a framework to assess the temporal and spatial stability of noisy, intermediate-scale quantum (NISQ) devices by quantifying fluctuations in key performance metrics—gate fidelity, duty cycle, and addressability—using the Hellinger distance. The study reveals significant temporal and spatial variations in these metrics across 22 months of data, indicating that current NISQ devices are unreliable beyond short timescales, undermining reproducibility of quantum computing results.

ABSTRACT

Noisy, intermediate-scale quantum (NISQ) computing devices offer opportunities to test the principles of quantum computing but are prone to errors arising from various sources of noise. Fluctuations in the noise itself lead to unstable devices that undermine the reproducibility of NISQ results. Here we characterize the reliability of NISQ devices by quantifying the stability of essential performance metrics. Using the Hellinger distance, we quantify the similarity between experimental characterizations of several NISQ devices by comparing gate fidelities, duty cycles, and register addressability across temporal and spatial scales. Our observations collected over 22 months reveal large fluctuations in each metric that underscore the limited scales on which current NISQ devices may be considered reliable.

Motivation & Objective

  • To address the critical challenge of reproducibility in NISQ quantum computing due to unstable device behavior over time and space.
  • To define and quantify device stability as consistent performance across temporal and spatial scales within a tolerance.
  • To evaluate the reliability of current NISQ devices using metrics aligned with DiVincenzo's criteria for quantum computing.
  • To identify the limits of reproducibility in experimental quantum computing based on measurable fluctuations in device performance.
  • To provide a statistical framework for assessing device stability that supports long-term benchmarking and validation.

Proposed method

  • Quantify device stability using the Hellinger distance to compare probability distributions of performance metrics across time and space.
  • Measure gate fidelity via randomized benchmarking of the 2-qubit Clifford group to estimate error per gate and compute $ F_G = 1 - \epsilon_G $.
  • Calculate duty cycle $ \tau = T_2 / T_G $, where $ T_2 $ is the average decoherence time and $ T_G $ is the gate duration.
  • Assess register addressability using normalized mutual information $ \eta $, with fidelity $ F_A $ derived from entangled or separable fiducial states.
  • Use a one-month sliding window to compute running Hellinger distances for temporal stability analysis.
  • Collect and analyze data from IBM’s yorktown and toronto devices over 22 months to evaluate stability across multiple metrics.

Experimental results

Research questions

  • RQ1How do key performance metrics—gate fidelity, duty cycle, and addressability—fluctuate over time and across different qubit pairs in NISQ devices?
  • RQ2To what extent do temporal and spatial variations in device parameters undermine the reproducibility of quantum computing benchmarks?
  • RQ3Can the Hellinger distance effectively quantify the similarity between performance distributions across different time windows and spatial regions?
  • RQ4What are the practical limits of reliability for current NISQ devices based on observed metric fluctuations?
  • RQ5How do variations in initialization fidelity, gate fidelity, and addressability correlate with one another across different qubit pairs?

Key findings

  • The duty cycle for the CNOT gate on the yorktown device (qubit pair 0,1) showed significant temporal variation, with Hellinger distance indicating substantial distributional shifts over time.
  • Addressability in the toronto device varied widely across qubit pairs, with the lowest value of 0.8875 for pair (23,21) and the highest of 0.9989 for pair (11,13), indicating inconsistent qubit coupling.
  • The Hellinger distance revealed distinguishable differences in stability across metrics, with the duty cycle showing the most pronounced temporal fluctuations.
  • Fluctuations in gate fidelity and initialization fidelity were correlated with variations in addressability, particularly in non-nearest-neighbor pairs.
  • The study found that current NISQ devices exhibit unreliable performance beyond short timescales, limiting the reproducibility of experimental results.
  • Even with calibration immediately before execution, device parameters such as decoherence time and gate duration vary significantly, undermining long-term consistency.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint