Skip to main content
QUICK REVIEW

[Paper Review] Status on the DESIR High Resolution Separator Commissioning

J. Michaud, P. Alfaurt|arXiv (Cornell University)|Mar 21, 2022
Nuclear Physics and ApplicationsPhysics and Astronomy4 citations
TL;DR

The DESIR High Resolution Separator (HRS) at GANIL achieves a mass resolution of R = 25,000 with 70% transmission for a 25 keV 133Cs+ beam, using mirror-symmetric optics, a 48-pole electrostatic multipole for third-order aberration correction, and precise emittance-based tuning. Commissioning results confirm its status as one of the most advanced in-flight mass separators, with high-fidelity beam control and resolution through advanced diagnostics and simulation-driven correction of optical aberrations up to third order.

ABSTRACT

Many nuclear reactions used to create radioactive isotopes for nuclear research produce, in addition to the isotope of interest, many contaminants, which are often produced in much larger amounts than the isotope of interest. Many installations using the ISOL approach are therefore equipped with high-resolution mass separators to remove at least isotopes with a different mass number. In the present paper, we present the results of the commissioning of the DESIR HRS presently under development at LP2I Bordeaux (formerly CENBG). Optical aberrations are corrected up to 3rd order and a mass resolution of M/$Δ$M of 25000 is reached with a transmission of about 70% for a 133Cs+ beam at 25 keV.

Motivation & Objective

  • To develop and commission a high-resolution mass separator (HRS) for the DESIR facility at GANIL to purify exotic radioactive ion beams.
  • To correct optical aberrations up to third order in a magnetic separator using mirror symmetry and a 48-pole electrostatic multipole.
  • To achieve a design mass resolution of R = 20,000 while maintaining high transmission and low energy dispersion.
  • To implement advanced diagnostics and control systems for real-time beam characterization and tuning.
  • To validate the HRS performance using 133Cs+ beams at 25 keV, demonstrating resolution and transmission close to design goals.

Proposed method

  • The HRS employs two 90° magnetic dipoles with 36° entrance/exit angles and a mirror-symmetric layout to inherently cancel second-order aberrations.
  • A 48-pole electrostatic multipole with independently controllable electrodes generates up to fifth-order multipole fields, enabling precise correction of higher-order optical aberrations.
  • Beam diagnostics include six profilers, four Faraday cups, four RMN probes, six slit sets, and an emittance-meter for real-time beam characterization.
  • The control system uses EPICS to remotely manage all components, including correction coils and multipole voltages.
  • Aberration correction is guided by emittance measurements and simulations using Zgoubi and COSY, with a software tool (CorrAb) for auto-tuning based on emittance figure patterns.
  • Pole reshaping of the dipoles is simulated and planned to reduce residual hexapolar corrections and improve field homogeneity.

Experimental results

Research questions

  • RQ1Can a high-resolution magnetic separator achieve R = 25,000 resolution with high transmission for low-energy radioactive ion beams?
  • RQ2How effectively can third-order optical aberrations be corrected in a mirror-symmetric HRS using a 48-pole electrostatic multipole?
  • RQ3To what extent can emittance-based diagnostics and auto-tuning software (CorrAb) improve beam quality and resolution?
  • RQ4What impact does dipole pole reshaping have on reducing required multipole corrections and improving field homogeneity?
  • RQ5Can the HRS maintain low energy dispersion (<1 eV) while achieving high mass resolution and high transmission?

Key findings

  • The DESIR HRS achieved a mass resolution of R = 25,000 for a 25 keV 133Cs+ beam, measured via a 1.25 eV energy shift between two beam positions separated by more than their FWHM.
  • Transmission of approximately 70% was achieved for a 1 mm beam at 25 keV, indicating high efficiency in beam purification.
  • Optical aberrations up to third order were successfully corrected using a combination of mirror symmetry, multipole fields, and emittance-based tuning.
  • The 48-pole multipole enabled precise control of up to fifth-order fields, with voltage scaling allowing energy-dependent tuning.
  • Simulations confirmed that reshaping the inner poles of the dipoles to a 6.94 m radius reduces required hexapolar correction from 308 V to 150 V, improving stability and reducing higher-order distortions.
  • The use of CorrAb software for emittance figure analysis enables automated, iterative correction of aberrations, significantly improving tuning efficiency.