Skip to main content
QUICK REVIEW

[Paper Review] Temperature in Glass Slides: measurement using Phase Sensitive Optical Coherence Tomography and Computational Modeling

José M. Folgueiras, L. G. Chej|arXiv (Cornell University)|Mar 18, 2026
Optical Coherence Tomography ApplicationsEngineering0 citations
TL;DR

The paper demonstrates a phase-sensitive optical coherence tomography method using a common-path setup to measure temperature-dependent optical-path differences in a 1-mm soda-lime glass slide, calibrated from 20–52°C, with theoretical and numerical modeling validating the approach.

ABSTRACT

Phase-sensitive optical coherence tomography (PhS-OCT) enables precise, contactless measurements of temperature-dependent changes in transparent solids. In this work, we used a common-path spectral-domain OCT system to measure optical path differences (OPD) in a 1-mm-thick soda-lime glass slide immersed in a thermal bath. The OPD variation showed a strong linear correlation with temperature in the range of 20-52°C, with an experimentally determined sensitivity of 12.4 +- 1.9 nm/°C. A theoretical model incorporating the thermo-optic and thermal expansion coefficients of glass was proposed to interpret the measurements, and numerical simulations based on finite volume methods were performed to account for spatial temperature gradients in the system. The simulations showed agreement with experimental results within 5% error, validating the approach. Additionally, repeatability tests using lateral scans at constant temperature demonstrated sub-10 nm stability, supporting future extensions to spatially resolved thermal mapping. This technique provides a low-cost platform for localized temperature sensing in solid transparent materials.

Motivation & Objective

  • Develop a contactless method to measure temperature inside a solid transparent material using PhS-OCT.
  • Establish a calibrated OPD–temperature relationship for a soda-lime glass slide in a controlled bath.
  • Provide uncertainty quantification and assess repeatability and potential for spatial thermal mapping.
  • Validate experimental measurements with a thermo-mechanical–optical model and finite-volume thermal simulations.

Proposed method

  • Use a common-path FD-OCT system where both surfaces of a glass slide form sample and reference arms.
  • Calibrate OPD versus temperature across 20–50°C using controlled thermal bath experiments.
  • Retrieve phase from multiple points within the Maximum Amplitude Zone to improve accuracy and avoid phase-wrapping artifacts.
  • Model OPD changes as Δz ≈ L( dn/dT + β n ) ΔT with material-specific dn/dT and β, and compare with experimental slopes.
  • Perform 3D OpenFOAM-based conjugate heat transfer simulations to map temperature distribution and validate sensor readings.
  • Quantify measurement uncertainty including OPD repeatability and slope uncertainty.
Figure 1: Schematic of the low-coherence interferometer setup. Key components: (a) SuperK white-light laser, (b) 50:50 fiber beam splitter, (c) collimator (d) HR4000 spectrometer.
Figure 1: Schematic of the low-coherence interferometer setup. Key components: (a) SuperK white-light laser, (b) 50:50 fiber beam splitter, (c) collimator (d) HR4000 spectrometer.

Experimental results

Research questions

  • RQ1Can phase-sensitive OCT provide reliable, contactless temperature measurements inside a solid glass substrate?
  • RQ2What is the calibrated OPD–temperature relationship for soda-lime glass in the 20–50°C range, and how well does theory match experiment?
  • RQ3How uniform is the temperature in the water bath around the glass slide, and how does this affect OPD-based thermometry?
  • RQ4What are the repeatability and spatial profiling capabilities of the proposed method for potential 2D thermal mapping?

Key findings

  • OPD shows a strong linear correlation with temperature in 20–52°C with sensitivity 12.4 ± 1.9 nm/°C.
  • Measured OPD–temperature slope agrees with theoretical prediction (~13.5 nm/°C) within ~8.5%.
  • R² > 0.99 for all measurement series, demonstrating robust linearity between OPD and temperature.
  • MAPE between experimental and simulated temperatures is 4.97% across series S3 and S4.
  • Sub-10 nm repeatability in spatial OPD profiling enables potential detection of thermal gradients.
  • OPD-based temperature measurement achieves a low-cost, label-free approach suitable for localized thermal sensing in transparent solids.
Figure 2: Cross-sectional view of the temperature-controlled water bath assembly: (c) collimator (e) glass crystallizer, (f) glass slide, (g) plastic tube maintaining dry optical surface, (h) ceramic hot plate with PID controller, and (i) PT100 thermal sensor.
Figure 2: Cross-sectional view of the temperature-controlled water bath assembly: (c) collimator (e) glass crystallizer, (f) glass slide, (g) plastic tube maintaining dry optical surface, (h) ceramic hot plate with PID controller, and (i) PT100 thermal sensor.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.