Skip to main content
QUICK REVIEW

[Paper Review] Towards Blood Flow in the Virtual Human: Efficient Self-Coupling of HemeLB

J. W. S. McCullough, Robin A. Richardson|arXiv (Cornell University)|Oct 8, 2020
Lattice Boltzmann Simulation StudiesEngineering29 references1 citations
TL;DR

This paper presents an efficient self-coupling strategy for the HemeLB lattice Boltzmann code, enabling high-fidelity 3D blood flow simulations across full human-scale arterial and venous vascular trees. By optimizing memory management, load balancing, and MPI communication, the method achieves near-linear scaling on over 100,000 cores and successfully couples arterial and venous flows at scale, marking a critical step toward simulating a full virtual human on exascale systems.

ABSTRACT

Many scientific and medical researchers are working towards the creation of a virtual human - a personalised digital copy of an individual - that will assist in a patient's diagnosis, treatment and recovery. The complex nature of living systems means that the development of this remains a major challenge. We describe progress in enabling the HemeLB lattice Boltzmann code to simulate 3D macroscopic blood flow on a full human scale. Significant developments in memory management and load balancing allow near linear scaling performance of the code on hundreds of thousands of computer cores. Integral to the construction of a virtual human, we also outline the implementation of a self-coupling strategy for HemeLB. This allows simultaneous simulation of arterial and venous vascular trees based on human-specific geometries.

Motivation & Objective

  • To enable high-fidelity 3D blood flow simulation across full human-scale vascular trees using the HemeLB lattice Boltzmann code.
  • To overcome computational bottlenecks in memory management and load balancing for large-scale simulations on exascale architectures.
  • To implement and validate a self-coupling strategy that synchronously simulates arterial and venous hemodynamics using patient-specific geometries.
  • To demonstrate the feasibility of simulating complex, coupled hemodynamic flows at the scale of the entire human vasculature.
  • To lay the groundwork for future validation and extension of HemeLB toward a complete, multi-scale virtual human model.

Proposed method

  • Adapted HemeLB to use next-generation MPI for efficient large-data communication across distributed memory systems.
  • Implemented advanced memory management and load balancing techniques to optimize performance on large-scale CPU clusters.
  • Developed a self-coupling framework allowing independent HemeLB instances to exchange flow data at shared boundary interfaces between arterial and venous trees.
  • Used patient-specific 3D vascular geometries reconstructed from medical imaging to define arterial and venous domains.
  • Applied the lattice Boltzmann method to solve the Navier-Stokes equations in complex, sparse vascular geometries with high spatial resolution.
  • Conducted proof-of-concept simulations on human leg vasculature to validate coupling stability and scalability.

Experimental results

Research questions

  • RQ1Can HemeLB achieve near-linear scaling on over 100,000 CPU cores when simulating full human-scale blood flow?
  • RQ2How effectively can arterial and venous vascular trees be coupled in a single simulation using self-coupling of HemeLB?
  • RQ3What performance bottlenecks arise when coupling multiple HemeLB instances, and how can they be mitigated?
  • RQ4Can the self-coupling strategy accurately reconstruct hemodynamic features such as wall shear stress and flow distribution at scale?
  • RQ5What computational and algorithmic improvements are required to extend this approach to a full virtual human model?

Key findings

  • HemeLB achieved near-linear scaling performance on up to 100,000 CPU cores, demonstrating strong scalability for large-scale 3D blood flow simulations.
  • The self-coupling strategy successfully communicated flow data across hundreds of boundary points between arterial and venous trees, enabling synchronized simulation.
  • The method enabled simulation of human-scale vascular geometries with over 10^10 lattice sites, approaching the scale required for full virtual human modeling.
  • The implementation reduced communication overhead through optimized MPI behavior and streamlined internal data structures, improving overall efficiency.
  • Proof-of-concept simulations on human leg vasculature successfully reproduced expected dynamic flow features, including complex velocity and shear stress distributions.
  • The study establishes a foundation for future validation against physiological data and extension to multi-scale, multi-physics virtual human simulations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.