Skip to main content
QUICK REVIEW

[Paper Review] Transferable Deep Learning Power System Short-Term Voltage Stability Assessment with Physics-Informed Topological Feature Engineering

Zijian Feng, Xin Chen|arXiv (Cornell University)|Mar 13, 2023
Power System Optimization and StabilityEngineering3 citations
TL;DR

This paper proposes a transferable deep learning model for short-term voltage stability (STVS) assessment by engineering topology-aware and physics-informed voltage dynamic features from PMU data. The model achieves 99.68% accuracy after fine-tuning on new grid topologies, demonstrating strong generalization and robustness to PMU errors.

ABSTRACT

Deep learning (DL) algorithms have been widely applied to short-term voltage stability (STVS) assessment in power systems. However, transferring the knowledge learned in one power grid to other power grids with topology changes is still a challenging task. This paper proposed a transferable DL-based model for STVS assessment by constructing the topology-aware voltage dynamic features from raw PMU data. Since the reactive power flow and grid topology are essential to voltage stability, the topology-aware and physics-informed voltage dynamic features are utilized to effectively represent the topological and temporal patterns from post-disturbance system dynamic trajectories. The proposed DL-based STVS assessment model is tested under random operating conditions on the New England 39-bus system. It has 99.99\% classification accuracy of the short-term voltage stability status using the topology-aware and physics-informed voltage dynamic features. In addition to high accuracy, the experiments show good adaptability to PMU errors. Moreover, The proposed STVS assessment method has outstanding performance on new grid topologies after fine-tuning. In particular, the highest accuracy reaches 99.68\% in evaluation, which demonstrates a good knowledge transfer ability of the proposed model for power grid topology change.

Motivation & Objective

  • Address the challenge of transferring STVS assessment models across power grids with changing topologies.
  • Improve model generalization by incorporating physical principles and grid topology into feature engineering.
  • Develop a robust, data-driven STVS assessment framework that maintains high accuracy under PMU measurement errors.
  • Demonstrate transfer learning effectiveness for new grid configurations through fine-tuning on unseen topologies.
  • Enable real-time, accurate STVS assessment using PMU data without relying on detailed geographic or system-specific information.

Proposed method

  • Engineer topology-aware voltage dynamic features from raw PMU data using reactive power flow and grid topology information.
  • Incorporate physics-informed constraints into feature construction to reflect voltage stability mechanisms, especially related to induction motors and load dynamics.
  • Use a convolutional neural network (CNN) as the classifier to map engineered features to STVS status (stable/unstable).
  • Apply transfer learning by pre-training the model on the standard New England 39-bus system and fine-tuning on target topologies with modified line configurations.
  • Generate 12 target-domain datasets by disconnecting one or two lines in the 39-bus system under random operating conditions.
  • Evaluate performance using standard metrics: accuracy, precision, recall, and F1-score across all test scenarios.

Experimental results

Research questions

  • RQ1Can topology-aware and physics-informed feature engineering improve the transferability of deep learning models for STVS assessment across different power grid topologies?
  • RQ2How does the proposed model perform under PMU measurement errors compared to conventional data-driven methods?
  • RQ3To what extent can a pre-trained model generalize to new power system topologies after fine-tuning?
  • RQ4What is the impact of increasing topological changes (e.g., multiple line disconnections) on the model’s transfer performance?
  • RQ5Can the model maintain high accuracy without retraining from scratch when applied to new grid configurations?

Key findings

  • The proposed model achieved 99.99% classification accuracy on the original New England 39-bus system using the engineered features.
  • After fine-tuning, the model reached a peak accuracy of 99.68% on the most complex topology change scenario (two lines disconnected), demonstrating strong transferability.
  • Even without fine-tuning, direct transfer achieved over 94% accuracy on all target datasets, with the lowest at 88.76% for scenarios involving two disconnections.
  • The model showed robustness to PMU errors, maintaining high performance across all tested conditions.
  • Fine-tuning consistently improved performance across all 12 target datasets, with F1-scores exceeding 98% in most cases.
  • The highest accuracy (99.68%) was achieved on dataset $G_4$, corresponding to the disconnection of line 4-14, indicating strong generalization to specific topology changes.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.