TL;DR

This paper introduces a universal adaptive optics method for microscopy using a physics-informed neural network embedded in the control loop, enabling fast, robust, and transferable aberration correction across two-photon, three-photon, and widefield 3D structured illumination microscopy. The approach outperforms conventional sensorless AO by leveraging tailored loss functions and physical insights, achieving diffraction-limited imaging under challenging conditions such as specimen motion and low signal-to-noise ratios.

ABSTRACT

The resolution and contrast of microscope imaging is often affected by aberrations introduced by imperfect optical systems and inhomogeneous refractive structures in specimens. Adaptive optics (AO) compensates these aberrations and restores diffraction limited performance. A wide range of AO solutions have been introduced, often tailored to a specific microscope type or application. Until now, a universal AO solution -- one that can be readily transferred between microscope modalities -- has not been deployed. We propose versatile and fast aberration correction using a physics-based machine learning (ML) assisted wavefront-sensorless AO control method. Unlike previous ML methods, we used a bespoke neural network (NN) architecture, designed using physical understanding of image formation, that was embedded in the control loop of the microscope. The approach means that not only is the resulting NN orders of magnitude simpler than previous NN methods, but the concept is translatable across microscope modalities. We demonstrated the method on a two-photon, a three-photon and a widefield three-dimensional (3D) structured illumination microscope. Results showed that the method outperformed commonly-used modal-based sensorless AO methods. We also showed that our ML-based method was robust in a range of challenging imaging conditions, such as extended 3D sample structures, specimen motion, low signal to noise ratio and activity-induced fluorescence fluctuations. Moreover, as the bespoke architecture encapsulated physical understanding of the imaging process, the internal NN configuration was no-longer a ``black box'', but provided physical insights on internal workings, which could influence future designs.

Motivation & Objective

  • To develop a universal adaptive optics solution transferable across diverse microscopy modalities, overcoming limitations of existing modality-specific AO systems.
  • To address the inefficiency and slow convergence of conventional sensorless AO methods that rely on iterative optimization of scalar image quality metrics.
  • To embed a physics-informed neural network directly into the microscope control loop for real-time, high-performance aberration correction.
  • To improve robustness under challenging imaging conditions, including specimen motion, low signal-to-noise ratio, and fluorescence fluctuations.
  • To make the neural network's internal operation interpretable by embedding physical principles of image formation, moving beyond the 'black box' paradigm.

Proposed method

  • A bespoke neural network architecture is designed using physical understanding of image formation, incorporating domain-specific loss functions derived from optical physics.
  • The method uses wavefront-sensorless adaptive optics (AO) with a machine learning (ML) control loop that directly maps image data to optimal deformable mirror (DM) corrections.
  • Three distinct image quality metrics are used as loss functions: intensity-based, Fourier-based (y_F), sharpness-based (y_S), and frequency-threshold (y_T), each tailored to specific microscope modalities.
  • The neural network is trained using data pre-processed with knowledge of the microscope’s point spread function (PSF) and spatial frequency response, enhancing generalization.
  • The trained network is embedded directly into the microscope’s real-time control system, enabling online, adaptive correction without external wavefront sensing.
  • The approach is validated on three distinct microscopes: two-photon, three-photon, and widefield 3D structured illumination microscopy (3D-SIM).

Experimental results

Research questions

  • RQ1Can a single, embedded neural network architecture enable effective and universal aberration correction across diverse microscopy modalities?
  • RQ2How does a physics-informed neural network improve convergence speed and robustness compared to conventional sensorless AO methods?
  • RQ3To what extent can the neural network’s internal representations provide physical insights into the imaging process, rather than remaining a black box?
  • RQ4How does the method perform under challenging conditions such as specimen motion, low signal-to-noise ratio, and fluorescence fluctuations?
  • RQ5Can the use of multiple, physics-motivated loss functions enhance image quality and correction accuracy across different imaging systems?

Key findings

  • The proposed MLAO method outperformed conventional modal-based sensorless AO methods in all tested microscopy systems, achieving superior image contrast and resolution.
  • The method demonstrated robust performance under low signal-to-noise conditions, maintaining effective aberration correction even with noisy or fluctuating fluorescence signals.
  • Specimen motion during imaging did not significantly degrade correction performance, as the method adapted quickly to dynamic changes.
  • The use of multiple, physics-motivated loss functions (y_F, y_S, y_T) enabled effective optimization across different imaging modalities, including widefield 3D-SIM where traditional metrics fail.
  • The embedded neural network’s internal structure provided interpretable insights into the imaging process, linking learned corrections to physical aberration characteristics.
  • The method achieved diffraction-limited performance across all three microscope types, confirming its universality and transferability.