Skip to main content
QUICK REVIEW

[Paper Review] Voluminous D2 source for intense cold neutron beam production at the ESS

E. B. Klinkby, K. E. Batkov|arXiv (Cornell University)|Jan 23, 2014
Nuclear Physics and ApplicationsPhysics and Astronomy1 references5 citations
TL;DR

This paper proposes a voluminous liquid D₂ moderator beneath the target at the European Spallation Source (ESS) to produce intense cold neutron beams for fundamental physics experiments. Using MCNPX simulations, it demonstrates that a 25 cm × 25 cm × 20.6 cm D₂ moderator in a through-going beam tube can deliver 3–4 times higher neutron beam intensity (A×B) than the baseline para-hydrogen moderator, with minimal impact on the brightness of the primary scattering moderator above when optimally positioned.

ABSTRACT

The development of the flat moderator concept at ESS recently opened up the possibility that a single flat moderator above the target could serve all the scattering instruments, that rely on high brightness. This would allow for the introduction of a fundamentally different moderator below the target for the complementary needs of certain fundamental physics experiments. To facilitate experiments depending on the total number of neutrons in a sizable beam, the option of a voluminous D2 moderator, in a large cross-section extraction guide is discussed and its neutronic performance is assessed.

Motivation & Objective

  • To explore the feasibility of a large-volume D₂ moderator beneath the ESS target to enhance cold neutron beam intensity for fundamental physics experiments.
  • To assess the impact of such a moderator on the performance of the primary flat para-hydrogen moderator used for neutron scattering instruments.
  • To evaluate the neutron transport and brightness performance of a D₂ moderator in a through-going beam tube with varying reflector and pre-moderator configurations.
  • To optimize the D₂ moderator geometry and materials to maximize neutron yield for beam experiments while minimizing interference with existing scattering beam lines.
  • To determine whether a D₂ moderator can significantly outperform the baseline TDR para-hydrogen moderator in terms of total neutron flux for experiments dependent on beam intensity.

Proposed method

  • A 25 cm × 25 cm × 20.6 cm rectangular liquid D₂ moderator (19 K, 1/3 para-deuterium, 2/3 ortho-deuterium) is modeled in a through-going beam tube beneath the ESS target wheel.
  • The moderator is encapsulated in 3 mm aluminum and surrounded by a variable-thickness water pre-moderator (1–4 cm) on all sides except the neutron-extraction face.
  • The simulation uses MCNPX to model neutron transport, with a lead reflector (130 cm diameter) replacing steel in the baseline design to improve neutron recycling and brightness.
  • Three cases are simulated: reference (no D₂ moderator), Case 1a (D₂ moderator at top of beam tube), and Case 1b (D₂ moderator lowered by 10 cm).
  • Neutron brightness is evaluated via F5 tallies at 5 m distance, with flux integrated over 0–5 meV to compute A×B (beam area × brightness) for comparison.
  • The performance of the D₂ moderator is compared to the ESS Technical Design Report (TDR) para-hydrogen moderator using a 12 cm × 12 cm extraction aperture.

Experimental results

Research questions

  • RQ1Can a large-volume D₂ moderator placed below the ESS target significantly increase cold neutron beam intensity for fundamental physics experiments?
  • RQ2What is the impact of a D₂ moderator on the brightness of the primary para-hydrogen moderator used for neutron scattering?
  • RQ3How does the position of the D₂ moderator (1a vs. 1b) affect the brightness of the upper para-hydrogen moderator?
  • RQ4To what extent can the use of a lead reflector instead of steel enhance the performance of the D₂ moderator and the upper moderator?
  • RQ5Can the A×B product (beam area × brightness) of the D₂ moderator exceed that of the baseline TDR para-hydrogen moderator?

Key findings

  • The D₂ moderator in Case 1a (at the top of the beam tube) reduces the brightness of the upper para-hydrogen moderator by approximately 15% compared to the reference case.
  • When the D₂ moderator is lowered by 10 cm (Case 1b), the brightness loss to the upper para-hydrogen moderator is negligible, effectively vanishing.
  • The A×B product for the D₂ moderator in Case 1a is 4.27 × 10¹⁵ n/sr/s, which is 3.6 times higher than the TDR para-hydrogen moderator’s 1.17 × 10¹⁵ n/sr/s.
  • In Case 1b, the A×B product is 2.85 × 10¹⁵ n/sr/s, still representing a 2.4-fold improvement over the TDR baseline.
  • The performance gain in A×B is attributed to the larger moderator area and the use of a lead reflector, which enhances neutron recycling and brightness.
  • The study confirms that a voluminous D₂ moderator can deliver 3–4 times higher cold neutron beam intensity than the baseline TDR para-hydrogen moderator, with minimal impact on scattering instrument performance when properly positioned.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.