[Paper Review] A Cosmic Ray Measurement Facility for ATLAS Muon Chambers

O. Biebel, M. Binder|ArXiv.org|Jul 30, 2003
Particle Detector Development and PerformancePhysics and Astronomy2 references10 citations
TL;DR

This paper presents a cosmic ray measurement facility at Ludwig-Maximilians-Universität Munich that enables high-precision calibration and testing of ATLAS MDT muon chambers prior to installation. Using cosmic ray muons, the facility measures individual anode wire positions with 8.3 μm precision in the chamber plane and 27 μm perpendicularly, achieving sub-20 μm accuracy for standalone muon momentum reconstruction in ATLAS.

ABSTRACT

Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map the positions of the anode wires within the chambers with the precision needed for standalone muon momentum measurement in ATLAS, and to gain experience in the operation of the chambers and on-line calibration procedures. Until the start of muon chamber installation in ATLAS, 88 chambers built at the Max Planck Institute for Physics in Munich have to be commissioned and calibrated. With a data taking period of one day individual wire positions can be measured with an accuracy of 8.3 micrometers in the chamber plane and 27 micrometers in the direction perpendicular to that plane.

Motivation & Objective

  • To commission and calibrate 88 ATLAS MDT muon chambers built at MPI Munich before installation.
  • To measure the 3D positions of anode wires within MDT chambers with sub-20 μm precision to enable standalone muon momentum measurement.
  • To validate chamber geometry and alignment using cosmic ray muons and compare results with X-ray tomography.
  • To develop and test on-line calibration procedures and alignment systems for large-scale muon spectrometer operation.
  • To ensure mechanical and electronic stability of chambers under controlled environmental conditions.

Proposed method

  • A cosmic ray trigger system uses three scintillator hodoscopes (one upper layer, two staggered lower layers) to detect muons with momentum >600 MeV.
  • Muon tracks are reconstructed using drift times in MDT chambers, with time resolution <800 ps and position resolution of 8 cm in the x-direction.
  • Wire position is determined by measuring drift time to the anode wire and applying an r-t relation calibrated via X-ray tomography.
  • Contact-free alignment systems (RasNik and capacitive sensors) monitor chamber positions with <5 μm precision.
  • Geometric parameters such as layer offsets, grid constants, and tilts are extracted from cosmic ray data using track fitting and residual analysis.
  • Data selection includes cuts on hodoscope hits, track quality, and estimated muon energy to reduce background and improve resolution.

Experimental results

Research questions

  • RQ1Can cosmic ray measurements achieve the required 20 μm wire position accuracy for standalone muon momentum reconstruction in ATLAS?
  • RQ2How does the precision of wire position measurement from cosmic rays compare to X-ray tomography results?
  • RQ3What is the achievable precision for measuring layer offsets, grid constants, and angular misalignments in MDT chambers?
  • RQ4Can the facility reliably calibrate and commission 88 MDT chambers at a rate of up to two per week?
  • RQ5How do environmental and alignment effects impact the measurement resolution and consistency?

Key findings

  • The Cosmic Ray Measurement Facility achieves a wire position resolution of 8.3 μm in the chamber plane and 27 μm perpendicular to it after 28 hours of data taking.
  • The facility measures layer offsets with a precision of 1.8 μm and grid constants with 0.15 μm resolution.
  • Layer shifts in the z-direction are measured with 4.4 μm precision, and tilt angles around the x-axis with 17×10⁻⁶ rad precision.
  • The cosmic ray measurements of wire positions show a 23 μm RMS difference from X-ray tomography results, indicating the facility's resolution is limited by its own system.
  • Measurements of layer shifts and grid constants are in excellent agreement with tomography data, validating the facility’s calibration accuracy.
  • The facility successfully supports the commissioning of 88 BOS-type MDT chambers at a rate of up to two per week, meeting the ATLAS installation timeline.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint