TL;DR

This paper presents a 100-channel Picosec Micromegas detector with a 100 cm² active area, achieving sub-20 ps time resolution using a rigid ceramic/FR4 hybrid printed circuit board to ensure drift gap uniformity. The detector combines a CsI semi-transparent photocathode with a Micromegas amplification structure, and beam tests with 80 GeV/c muons demonstrate a time resolution of 17 ps using a thinner 180 μm drift gap and custom RF pulse amplifiers, marking a key advancement in large-area, high-precision timing gaseous detectors for high-energy physics.

ABSTRACT

The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm$^2$ suffered from degraded timing resolution due to the non-uniformity of the preamplification gap. A new 100 cm$^2$ detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over measured pads and a time resolution below 25 ps. More recent measurements with a new thinner drift gap detector module and newly developed RF pulse amplifiers show that the resolution can be enhanced to a level of 17~ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Motivation & Objective

  • Develop a large-area, multi-channel gaseous timing detector with sub-20 ps time resolution for high-energy physics applications.
  • Address non-uniformity in drift gap geometry that degraded timing performance in earlier 19-channel prototypes.
  • Design a mechanically stable, flat 100 cm² detector module using a rigid ceramic/FR4 hybrid printed circuit board to improve drift gap uniformity.
  • Achieve high timing resolution across all 100 channels over a large active area using optimized electronics and beam test validation.
  • Enable scalable, modular design for future high-rate, high-precision timing detectors in collider experiments.

Proposed method

  • Employed finite element analysis to simulate mesh tension and mechanical coupling, selecting a 4 mm thick ceramic core with 0.3 mm FR4 outer layers for improved planarity (<10 μm over 100 cm²).
  • Designed a 100-channel detector with a 180 μm drift gap and a semi-transparent CsI photocathode coupled to a Micromegas amplification structure using Ne:C2H6:CF4 gas mixture (80:10:10).
  • Implemented an automated timing scan method using a movable microchannel plate (MCP) stage, moving in a 2.5 mm × 2.5 mm grid every 1000 events to ensure even data coverage and 75% overlap for averaging imperfections.
  • Used custom 10-channel, 38 dB, 650 MHz RF pulse amplifiers with built-in discharge protection, based on a reference design, to improve signal fidelity and timing resolution.
  • Digitized signals with high-bandwidth oscilloscopes and applied a saturation amplitude time (SAT) analysis to extract time resolution across pads.
  • Conducted beam tests at CERN with 80 GeV/c muons during two RD51 campaigns in July and October 2022, focusing on single-pad response and signal sharing.

Experimental results

Research questions

  • RQ1Can a mechanically rigid 100 cm² Micromegas detector with a 180 μm drift gap maintain sub-20 ps time resolution across all 100 channels?
  • RQ2How does the use of a ceramic/FR4 hybrid PCB improve drift gap uniformity and timing performance compared to earlier flexible PCBs?
  • RQ3To what extent does the new custom RF amplifier chain enhance timing resolution compared to standard electronics?
  • RQ4Is the timing response uniform across the entire 100 cm² active area, and how does signal sharing affect resolution?
  • RQ5Can an automated scanning method with synchronized event recording provide reliable, high-resolution timing characterization over large-area detectors?

Key findings

  • The 100-channel PICOSEC Micromegas detector achieved a time resolution of 17.1 ps on average across all measured pads, with individual RMS values ranging from 16.4 ps to 17.9 ps.
  • The use of a rigid ceramic/FR4 hybrid PCB reduced drift gap non-uniformity, preserving the excellent timing performance of the single-channel prototype across a large area.
  • Beam tests with 80 GeV/c muons confirmed that the 180 μm drift gap configuration maintained high timing resolution, with the best results reaching 16.4 ps on pad 28.
  • The automated timing scan method enabled uniform data collection over the entire detector area, with 75% overlap between scan points to average out imperfections.
  • Signal sharing and time resolution were found to be consistent across pads, with no significant degradation in performance across the 100-channel array.
  • The integration of custom RF amplifiers with 38 dB gain and discharge protection improved signal fidelity and contributed to the sub-20 ps timing resolution.