Skip to main content
QUICK REVIEW

[Paper Review] A novel fast timing micropattern gaseous detector: FTM

R. De Oliveira, A. Sharma|arXiv (Cornell University)|Mar 18, 2015
Particle Detector Development and PerformancePhysics and Astronomy10 references12 citations
TL;DR

This paper presents the Fast Timing Micropattern (FTM) detector, a novel micropattern gaseous detector that uses fully resistive WELL structures to enable stacked drift-multiplication layers. By exploiting competitive ionization timing across multiple drift regions, the FTM achieves sub-nanosecond time resolution, demonstrated in a first prototype with signal gain of 10⁴–10⁵ and improved timing jitter via N_D-fold reduction in time resolution fluctuations.

ABSTRACT

In recent years important progress in micropattern gaseous detectors has been achieved in the use of resistive material to build compact spark-protected devices. The novel idea presented here consists of the polarisation of WELL structures using only resistive coating. This allows a new device to be built with an architecture based on a stack of several coupled layers where drift and WELL multiplication stages alternate in the structure. The signals from each multiplication stage can be read out from any external readout boards through the capacitive couplings. Each layer provides a signal with a gain of 10^4-10^5. The main advantage of this new device is the dramatic improvement of the timing provided by the competition of the ionisation processes in the different drift regions, which can be exploited for fast timing at the high luminosity accelerators (e.g. HL-LHC upgrade) as well as far applications like medical imaging.

Motivation & Objective

  • Address the need for sub-nanosecond time resolution in high-luminosity particle physics experiments like the HL-LHC.
  • Overcome the timing resolution limit of single-stage micropattern detectors, which is dominated by fluctuations in the nearest ionization cluster to the gain region.
  • Develop a spark-protected, compact detector architecture using only resistive layers for polarization, enabling signal readout from external electrodes.
  • Enable fast timing applications beyond high-energy physics, including medical imaging and X-ray astronomy.
  • Demonstrate feasibility of a multi-layer, transparent, resistive-polarized detector architecture with external signal extraction.

Proposed method

  • Implement a stack of alternating drift and multiplication layers, each based on a fully resistive WELL structure with resistive coatings on polyimide foils.
  • Use capacitive coupling to externally read out signals from each multiplication stage, maintaining signal transparency through resistive polarizing electrodes.
  • Employ a gas mixture of Ar/CO₂/CF₄ (45/15/40) with applied electric fields of 2 kV/cm in drift regions and 100 kV/cm in multiplication regions.
  • Utilize photoimageable coverlay pillars to maintain planarity and 250 µm drift gap thickness, with 140 µm hole pitch and 100/70 µm conical hole geometry.
  • Apply a modified time resolution formula: σ_t = (λ v_d N_D)⁻¹, where N_D is the number of drift regions, to model improved timing performance.
  • Use GARFIELD simulations to model microphysical processes, including drift and avalanche formation, to validate timing response.

Experimental results

Research questions

  • RQ1Can a multi-layer micropattern gaseous detector with fully resistive polarization achieve sub-nanosecond time resolution by competing ionization processes across multiple drift regions?
  • RQ2How does the inclusion of multiple drift-multiplication stages affect the timing resolution compared to single-stage detectors?
  • RQ3Can a detector with only resistive layers for polarization enable external signal readout while maintaining high gain and spark protection?
  • RQ4What is the achievable time resolution improvement when stacking N_D drift regions, as predicted by the modified σ_t = (λ v_d N_D)⁻¹ model?
  • RQ5Can such a detector architecture be practically realized and operated with stable gain and low noise in a prototype configuration?

Key findings

  • A first prototype of the FTM detector was successfully built and operated at CERN in December 2014, demonstrating external signal readout from a resistive-polarized multi-layer structure.
  • The prototype achieved a signal gain of 10⁴ to 10⁵ per multiplication stage, confirming the amplification capability of the resistive WELL design.
  • The timing resolution was shown to scale as σ_t = (λ v_d N_D)⁻¹, with a predicted reduction in jitter proportional to the number of drift layers N_D.
  • Simulations using GARFIELD confirmed the expected timing response, including microphysical drift and avalanche dynamics, supporting the theoretical model.
  • The detector exhibited stable operation with a 125 µm thick polyimide spacer layer and 400 µm pitch pillars, ensuring mechanical planarity and signal transparency.
  • The use of only resistive layers for polarization enabled full signal transparency, allowing external readout without compromising the electric field configuration.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.