[Paper Review] Automatic Myocardial Infarction Evaluation from Delayed-Enhancement Cardiac MRI using Deep Convolutional Networks
This paper proposes a two-stage deep learning framework for automatic myocardial infarction evaluation using delayed-enhancement cardiac MRI and clinical data. It employs separate U-Net-based networks for anatomical (left ventricle and myocardium) and pathological (infarct and no-reflow) segmentation, with refinement via myocardium masking, achieving 93% Dice for left ventricle and 84% for myocardium, and 93.3% classification accuracy using MRI data.
In this paper, we propose a new deep learning framework for an automatic myocardial infarction evaluation from clinical information and delayed enhancement-MRI (DE-MRI). The proposed framework addresses two tasks. The first task is automatic detection of myocardial contours, the infarcted area, the no-reflow area, and the left ventricular cavity from a short-axis DE-MRI series. It employs two segmentation neural networks. The first network is used to segment the anatomical structures such as the myocardium and left ventricular cavity. The second network is used to segment the pathological areas such as myocardial infarction, myocardial no-reflow, and normal myocardial region. The segmented myocardium region from the first network is further used to refine the second network's pathological segmentation results. The second task is to automatically classify a given case into normal or pathological from clinical information with or without DE-MRI. A cascaded support vector machine (SVM) is employed to classify a given case from its associated clinical information. The segmented pathological areas from DE-MRI are also used for the classification task. We evaluated our method on the 2020 EMIDEC MICCAI challenge dataset. It yielded an average Dice index of 0.93 and 0.84, respectively, for the left ventricular cavity and the myocardium. The classification from using only clinical information yielded 80% accuracy over five-fold cross-validation. Using the DE-MRI, our method can classify the cases with 93.3% accuracy. These experimental results reveal that the proposed method can automatically evaluate the myocardial infarction.
Motivation & Objective
- To develop an automated method for detecting myocardial infarction and no-reflow regions from delayed-enhancement cardiac MRI (DE-MRI).
- To improve segmentation accuracy of anatomical structures (left ventricle and myocardium) and pathological regions using deep convolutional networks.
- To enable automatic classification of patients as normal or pathological using clinical information and/or DE-MRI data.
- To address challenges in medical image segmentation, including low-contrast boundaries, shape variability, and motion artifacts.
- To integrate clinical data with imaging features to enhance diagnostic classification performance.
Proposed method
- Uses two separate encoder-decoder convolutional neural networks: one for anatomical segmentation (left ventricle and myocardium), another for pathological segmentation (infarct, no-reflow, normal myocardium).
- Applies a masking strategy where the output of the anatomical network constrains the pathological network’s predictions to lie within the segmented myocardium region.
- Employs 2D $3\times3$ convolutions with ELU activation, batch normalization, and squeeze-and-excitation blocks in the network architecture.
- Uses $2\times2$ max-pooling for downsampling and $2\times2$ transposed convolutions for upsampling, with skip connections via concatenation.
- Preprocesses input images by zero-centering intensity values and normalizing by standard deviation, resizing to $256\times256$.
- Combines outputs from both networks into a final four-class segmentation map (LV, MYO, MI, normal MYO), evaluated in 3D using Dice, Hausdorff distance, and relative volume difference.
Experimental results
Research questions
- RQ1Can a deep learning framework accurately segment left ventricular cavity and myocardium from short-axis DE-MRI series?
- RQ2Can a cascaded network architecture effectively detect myocardial infarction and no-reflow regions while constraining predictions to the myocardial boundary?
- RQ3To what extent can clinical information alone or combined with DE-MRI improve automatic classification of myocardial infarction cases?
- RQ4How does the proposed method compare to state-of-the-art in segmentation accuracy and classification performance on the EMIDEC MICCAI 2020 challenge dataset?
- RQ5What are the limitations in pathological region segmentation, particularly in terms of overlap metrics like Dice and volume consistency?
Key findings
- The proposed method achieved a mean Dice score of 0.93 ± 0.018 for left ventricular cavity segmentation and 0.84 ± 0.03 for myocardium segmentation on the validation set.
- The average 3D Hausdorff distance was 6.5 mm for the left ventricle and 8.9 mm for the myocardium, indicating acceptable spatial accuracy.
- Classification using only clinical information yielded 80% accuracy in five-fold cross-validation.
- Classification using DE-MRI-derived pathological segmentation features achieved 93.3% accuracy, significantly outperforming clinical-only classification.
- Pathological segmentation showed lower overlap, with a Dice score of 0.40 ± 0.10 for myocardial infarction and 0.67 ± 0.15 for no-reflow regions, and relative volume differences of 0.242 and 0.375, respectively.
- The framework demonstrated robust performance on diverse image resolutions and clinical variations, validating its potential for clinical deployment.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.