Skip to main content
QUICK REVIEW

[Paper Review] Cascaded Convolutional Neural Network for Automatic Myocardial Infarction Segmentation from Delayed-Enhancement Cardiac MRI

Yichi Zhang|arXiv (Cornell University)|Dec 28, 2020
Cardiac Imaging and DiagnosticsMedicine9 references6 citations
TL;DR

This paper proposes a cascaded 2D-3D U-Net architecture for automatic myocardial infarction segmentation in delayed-enhancement cardiac MRI. It first uses a 2D U-Net for intra-slice coarse segmentation, then refines results with a 3D U-Net leveraging volumetric context, achieving state-of-the-art performance with a mean Dice score of 0.8786 for myocardium, 0.7124 for infarction, and 0.7851 for no-reflow on the MICCAI 2020 EMIDEC challenge dataset.

ABSTRACT

Automatic segmentation of myocardial contours and relevant areas like infraction and no-reflow is an important step for the quantitative evaluation of myocardial infarction. In this work, we propose a cascaded convolutional neural network for automatic myocardial infarction segmentation from delayed-enhancement cardiac MRI. We first use a 2D U-Net to focus on the intra-slice information to perform a preliminary segmentation. After that, we use a 3D U-Net to utilize the volumetric spatial information for a subtle segmentation. Our method is evaluated on the MICCAI 2020 EMIDEC challenge dataset and achieves average Dice score of 0.8786, 0.7124 and 0.7851 for myocardium, infarction and no-reflow respectively, outperforms all the other teams of the segmentation contest.

Motivation & Objective

  • To address the challenge of accurate automatic segmentation of myocardial infarction and related regions in delayed-enhancement cardiac MRI.
  • To improve segmentation accuracy by combining intra-slice (2D) and volumetric (3D) spatial information.
  • To develop a robust method that outperforms existing approaches in the MICCAI 2020 EMIDEC challenge for myocardial infarction segmentation.
  • To leverage spatial priors from 2D coarse outputs to enhance 3D refinement in regions with low inter-slice correlation.

Proposed method

  • A cascaded two-stage network architecture is proposed: first a 2D U-Net processes individual short-axis slices for coarse segmentation.
  • The 2D output is concatenated with the original 3D volume to serve as a spatial prior for the 3D U-Net in the second stage.
  • The 3D U-Net uses 3D convolutions to capture volumetric context and refine segmentation using inter-slice correlations.
  • Skip connections between encoder and decoder blocks in both 2D and 3D U-Nets preserve spatial localization and enhance feature learning.
  • A hybrid loss function combining cross-entropy and dice loss is used to improve foreground class attention during training.
  • Model inference uses 5-fold cross-validation with majority voting ensembling for final test set predictions.

Experimental results

Research questions

  • RQ1Can a cascaded 2D-3D U-Net architecture improve segmentation accuracy for myocardial infarction in DE-MRI compared to standalone 2D or 3D networks?
  • RQ2Does incorporating 2D coarse outputs as a spatial prior enhance 3D segmentation performance, especially in regions with low inter-slice resolution?
  • RQ3How does the proposed method compare to other entries in the MICCAI 2020 EMIDEC challenge in terms of Dice score and volumetric error?
  • RQ4To what extent does the method maintain robustness across diverse pathological and normal cases in the dataset?

Key findings

  • The proposed method achieved a mean Dice score of 0.8786 for myocardium segmentation on the EMIDEC test set, ranking first in the segmentation challenge.
  • For infarction segmentation, the method achieved a Dice score of 0.7124, significantly outperforming the 2D-only baseline (mean 0.558) and demonstrating strong refinement via 3D modeling.
  • The no-reflow segmentation achieved a Dice score of 0.7851, indicating effective detection of microvascular obstruction areas.
  • The method showed low variance across folds, with standard deviations of 0.005 for myocardium and 0.04 for infarction, indicating high robustness.
  • Volume difference (VolDif) and Hausdorff distance metrics confirmed improved geometric accuracy, with VolDif for myocardium averaging 9258.24 mm³ on the test set.
  • Post-processing steps, including removal of scattered voxels, further improved segmentation quality and reduced false positives.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.