[Paper Review] Comparing Poiseuille with 1D Navier-Stokes Flow in Rigid and Distensible Tubes and Networks
This study compares Poiseuille flow in rigid tubes and networks with time-independent 1D Navier-Stokes flow in elastic tubes and networks, using analytical relations and finite element models. It demonstrates that the two models yield significantly different flow predictions—especially in distensible systems—highlighting that they should not be used interchangeably due to fundamental differences in pressure dependence, nonlinearity, and physical fidelity.
A comparison is made between the Hagen-Poiseuille flow in rigid tubes and networks on one side and the time-independent one-dimensional Navier-Stokes flow in elastic tubes and networks on the other. Analytical relations, a Poiseuille network flow model and two finite element Navier-Stokes one-dimensional flow models have been developed and used in this investigation. The comparison highlights the differences between Poiseuille and one-dimensional Navier-Stokes flow models which may have been unjustifiably treated as equivalent in some studies.
Motivation & Objective
- To rigorously compare Poiseuille flow in rigid tubes/networks with 1D Navier-Stokes flow in distensible tubes/networks.
- To identify and quantify discrepancies between the two models under varying physical and geometric conditions.
- To assess the validity of treating Poiseuille and 1D Navier-Stokes models as equivalent in hemodynamic and porous media modeling.
- To evaluate the computational and numerical implications of using each model, including memory cost and solver convergence.
- To determine which model better captures physical reality in different flow scenarios, especially regarding pressure dependence and transient behavior.
Proposed method
- Developed an analytical Poiseuille network flow model based on constant conductance and conservation of flow at junctions.
- Formulated two finite element implementations of the 1D Navier-Stokes equations for elastic tubes, using two distinct pressure-area (p-A) constitutive relations.
- Applied the models to single tubes and fractal-like tube networks with varying generations (5 to 15), branching ratios, and geometric parameters.
- Used a linear system solver for the Poiseuille model (order N² memory) and iterative solvers for the nonlinear 1D Navier-Stokes model (order 4N² memory).
- Compared flow rates (QP vs. QN) across a range of parameters: α, β, μ, pressure magnitude, pressure limits, ρ, and network size.
- Evaluated model performance using independent metrics such as consistency with physical principles and experimental compliance.
Experimental results
Research questions
- RQ1How do Poiseuille and 1D Navier-Stokes models differ in their prediction of volumetric flow rate in single rigid and distensible tubes?
- RQ2What is the impact of tube distensibility and pressure-area constitutive laws on the divergence between Poiseuille and 1D Navier-Stokes flow predictions?
- RQ3How do parameters such as α, β, μ, and network topology affect the discrepancy between the two models in networked systems?
- RQ4In what ways do computational costs and solver convergence issues influence the reliability and practicality of each model?
- RQ5To what extent can Poiseuille flow accurately represent transient or spatially varying flow fields compared to 1D Navier-Stokes?
Key findings
- The Poiseuille and 1D Navier-Stokes models produce significantly different flow rate predictions, especially in distensible tubes, due to differing pressure dependencies: Poiseuille depends on pressure drop, while 1D Navier-Stokes depends on absolute inlet and outlet pressures.
- The 1D Navier-Stokes model is nonlinear and requires iterative solvers, leading to higher computational cost (4N² memory) and potential convergence issues, unlike the linear Poiseuille model solved in a single iteration.
- For networked systems, the parameters α and β in the pressure-area relation have the most substantial impact on discrepancies between the two models, while other parameters like μ and pressure magnitude show moderate or negligible effects in the studied cases.
- The Poiseuille model provides a linear pressure field and can directly compute pressure at interior points, whereas the 1D Navier-Stokes model's nonlinear pressure field does not allow this direct computation.
- The 1D Navier-Stokes model can simulate transient flows, while the Poiseuille model is inherently time-independent and can only approximate time-dependent behavior via sequential steady-state frames.
- The study cautions against treating the two models as interchangeable, especially in hemodynamic contexts, and emphasizes that model choice must be based on physical fidelity, not computational convenience.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.