[Paper Review] Detecting scrambling via statistical correlations between randomized measurements on an NMR quantum simulator
This paper demonstrates experimentally the detection of out-of-time-order correlators (OTOCs) in a 4-qubit NMR quantum simulator using statistical correlations from randomized measurements, bypassing the need for time-reversal operations or ancillary systems. The study validates both global and local protocols, showing excellent agreement between experimental, numerical, and theoretical OTOC values, confirming the feasibility of randomized measurement protocols for probing quantum information scrambling in chaotic many-body systems.
Out-of-time-order correlator (OTOC), been suggested as a measure of quantum information scrambling in quantum many-body systems, has received enormous attention recently. The experimental measurement of OTOC is quite challenging. The existing theoretical protocols consist in implementing time-reversal operations or using ancillary quantum systems, therefore only a few experiments have been reported. Recently, a new protocol to detect OTOC using statistical correlations between randomized measurements was put forward. In this work, we detect the OTOCs of a kicked-Ising model using this new measurement method on a 4-qubit nuclear magnetic resonance quantum simulator. In experiment, we use random Hamiltonian evolutions to generate the random operations that are required by the randomized OTOC detection protocol. Our experimental results are in good agreement with the theoretical predictions, thus confirming the feasibility of the protocols. Therefore, our work represents a step in exploring realistic quantum chaotic dynamics in complicated quantum systems.
Motivation & Objective
- To experimentally demonstrate a novel protocol for measuring out-of-time-order correlators (OTOCs) without requiring time-reversal operations or ancillary qubits.
- To validate the feasibility of using statistical correlations from randomized measurements to probe quantum information scrambling in many-body systems.
- To test both global and local randomized measurement protocols on a 4-qubit kicked-Ising model in an NMR quantum simulator.
- To compare experimental OTOC results with numerical simulations and analytical predictions, assessing protocol accuracy and error sources.
Proposed method
- The global protocol uses random unitary evolutions generated via a design Hamiltonian to simulate global random unitaries, applied before time evolution.
- The local protocol replaces global random unitaries with local random unitaries on individual qubits, simplifying experimental implementation.
- OTOCs are estimated from statistical correlations between measurement outcomes of the longitudinal spin operator $\langle \sigma_4^z \rangle$ after random unitary evolution and time evolution.
- The protocol relies on ensemble-averaged NMR signal measurements to extract $\langle I_z^4 \rangle$, which is proportional to $\langle \sigma_4^z \rangle$.
- Random unitaries are implemented using random Hamiltonian evolutions over a sequence of time steps, with 50 independent random realizations used per measurement.
- Theoretical OTOCs are computed numerically and analytically for comparison with experimental and simulated data.
Experimental results
Research questions
- RQ1Can statistical correlations from randomized measurements reliably detect OTOCs in a many-body quantum system without time-reversal operations?
- RQ2How does the performance of the local randomized protocol compare to the global protocol in terms of fidelity and experimental feasibility?
- RQ3To what extent do experimental results match theoretical predictions and numerical simulations in a 4-qubit NMR system?
- RQ4What are the dominant sources of error in the randomized measurement protocol for OTOC detection?
Key findings
- The experimental OTOC values for both global and local protocols show strong agreement with theoretical predictions and numerical simulations, confirming the protocol's validity.
- At $Jt = 1$ and $Jt = 32$, the statistical distributions of measurement outcomes align well with expected OTOC behavior, indicating successful scrambling detection.
- The divergence between numerical and theoretical OTOCs is attributed to insufficient sampling ($N_u = 50$), suggesting improved accuracy with larger sample sizes.
- Experimental data exhibit good agreement with numerical simulations, with deviations primarily due to state preparation errors, control inaccuracy, and decoherence.
- The local protocol successfully detects OTOCs with comparable fidelity to the global protocol, demonstrating its practicality for larger systems.
- The results validate the use of randomized measurement protocols as a scalable and robust method for probing quantum chaos and information scrambling in NMR and other quantum simulators.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.