Skip to main content
QUICK REVIEW

[Paper Review] Development of a one-dimensional position sensitive detector for Compton X-ray polarimeters

Abhay Kumar, Santosh V. Vadawale|arXiv (Cornell University)|Mar 26, 2026
Particle Detector Development and PerformancePhysics and Astronomy0 citations
TL;DR

This paper presents a two-end readout NaI(Tl) scintillator absorber with SiPMs to achieve 1-D interaction position and energy measurement for a hard X-ray Compton polarimeter (CXPOL).

ABSTRACT

The scientific potential of X-ray polarimetry has long been recognized, but the challenges in measuring polarization have left it largely unexplored, particularly in the hard X-ray regime. While tremendous advancement has been made in soft X-ray polarimetery, the lack of sensitive hard X-ray polarimeters and polarisation measurements continues to limit our understanding of high-energy astrophysical processes. With the development of hard X-ray mirrors, it is now possible to develop a sensitive focal plane hard X-ray polarimeter. One such effort is CXPOL, a prototype developed at PRL, India, which consists of a plastic scintillator as active scatterer readout by PMT surrounded by CsI(Tl) scintillators in cylindrical array with SiPM readout from one side. First results of the prototype have been demonstrated in 20 to 80 keV energy range. The sensitivity of the instrument can be significantly enhanced using faster and better light yield scintillator like NaI as absorbers. Further, the use of a position-sensitive scatterer and absorbers, can also provide spectroscopic information by measuring the interaction position along the length and from the known energy depositions in the detectors. Position sensitive detectors are also helpful in mitigating the systematic effects introduced by the off-axis events in the polarisation measurements. Here, we demonstrate the detection sensitivity in the 100x20x5 mm^3 NaI(Tl) scintillator absorber readout on both ends by SiPM arrays operating in co-incidence. In this work, we characterize the first prototype of this detector system and investigate the variation in energy and position resolution, and light output with irradiation position along the length of the detector. The two end readout in co-incidence also reduces the overall SiPM background per absorber by an order of magnitude, further enhancing the polarimetric sensitivity of the instrument.

Motivation & Objective

  • Motivate hard X-ray polarimetry and the need for spectro-polarimetric capability in the 20–80 keV range.
  • Develop a 1-D position-sensitive absorber detector to improve polarization measurements and provide spectral information.
  • Replace CsI(Tl) absorbers with NaI(Tl) and implement dual-end SiPM readout for full-length sensitivity.
  • Demonstrate detector performance along the scintillator length using Am-241 59.54 keV photons.
  • Evaluate energy resolution, position localization, efficiency, and background suppression in coincidence mode.

Proposed method

  • Replace CsI(Tl) absorbers with NaI(Tl) to boost light yield and decay time.
  • Use two SiPM arrays at the ends of a 100×20×5 mm3 NaI(Tl) scintillator to obtain 1-D position via end-to-end signal ratio ADC2/(ADC1+ADC2).
  • Couple scintillator ends to SiPMs with quartz windows and optical gels for improved light collection.
  • Develop a two-board readout: charge-sensitive preamplifiers/shapers and an FPGA-based coincidence/peak-detection chain with a 1 µs timing window.
  • Calibrate gain symmetry using center irradiation and Am-241 coincidence to correct ADC gains between ends.
  • Analyze energy by summing end signals (ADC1+ADC2) and fit spectra with two Gaussians for 59.54 keV and iodine escape peaks.

Experimental results

Research questions

  • RQ1Can a two-ended, 1-D position-sensitive NaI(Tl) absorber provide uniform sensitivity along the scintillator length for hard X-ray polarization measurements?
  • RQ2What are the energy resolution, positional accuracy, and coincidence efficiency achievable with dual-end SiPM readout in the 20–80 keV band?
  • RQ3How does two-end coincidence readout impact SiPM background and overall polarimetric sensitivity?
  • RQ4What optimizations (scintillator, wrapping, optics, electronics) are needed to reach ~20 keV thresholds and improved background rejection?

Key findings

  • Energy centroid at 59.54 keV shows higher values near the SiPM ends and lower at the center, indicating light collection variations along the length.
  • Energy resolution at 59.54 keV is ~30% at the ends and ~40% at the center, averaging ~34% along the length.
  • Average spatial (1-D) localization resolution is ~1.55 cm, with ~1.04–1.09 cm near the ends.
  • Two-end coincidence reduces SiPM background by about a factor of 10, improving polarimetric sensitivity.
  • Detector achieves >60% relative detection efficiency at 60 keV along the length with two-end coincidence mode.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.