Skip to main content
QUICK REVIEW

[Paper Review] Development of a PCI Based Data Acquisition Platform for High Intensity Accelerator Experiments

T. Higuchi, Hayato Fujii|ArXiv.org|May 28, 2003
Particle Detector Development and PerformancePhysics and Astronomy1 references18 citations
TL;DR

This paper presents a PCI-based data acquisition (DAQ) platform for high-intensity accelerator experiments, featuring a 9U-VME motherboard with four signal digitization modules, readout FIFOs, and a PMC slot for an on-board data compression CPU. The platform achieves 125 MB/s DMA transfer speed and demonstrates long-term and thermal stability, enabling high-throughput data logging at luminosities exceeding 10^35 cm⁻²s⁻¹.

ABSTRACT

Data logging at an upgraded KEKB accelerator or the J-PARC facility, currently under commission, requires a high density data acquisition platform with integrated data reduction CPUs. To follow market trends, we have developed a DAQ platform based on the PCI bus, a choice which permits a fast DAQ and a long expected lifetime of the system. The platform is a 9U-VME motherboard consisting of four slots for signal digitization modules, readout FIFOs for data buffering, and three PMC slots, on one of which resides a data reduction CPU. We have performed long term and thermal stability tests. The readout speed on the platform has been measured up to 125 MB/s in DMA mode.

Motivation & Objective

  • To develop a high-throughput, long-lived DAQ platform for future high-luminosity experiments at KEKB and J-PARC.
  • To address increasing data rates (500–1000 MB/s) and data sizes (50–100 kB/event) expected at luminosities >10^35 cm⁻²s⁻¹.
  • To reduce data volume through on-board data compression using a commercial CPU on a PMC card.
  • To ensure system longevity and modularity by leveraging the widely adopted PCI bus and PMC standard.
  • To achieve stable performance under extended operation and varying thermal conditions.

Proposed method

  • The DAQ platform is built on a 9U-VME motherboard with four slots for signal digitization modules and three PMC slots, one of which hosts a data compression CPU.
  • Data from front-end modules are transferred to readout FIFOs on the motherboard for buffering before being processed by the on-board CPU.
  • The processor uses a RadiSys EPC-6315 with an Intel Pentium III at 800 MHz, running Linux, to perform pedestal subtraction, hit suppression, and data compression.
  • A network interface on the SPIGOT board enables data transfer to a remote PC for monitoring and validation.
  • Performance was tested using pseudo-data with a 10 Hz trigger rate, simulating 100 MHz sampling and 500 ns window on 16-channel 8-bit digitization.
  • Long-term and thermal stability were evaluated over 48 hours at room temperature and 77 hours from 10°C to 50°C.

Experimental results

Research questions

  • RQ1Can a PCI-based DAQ platform achieve sufficient data transfer bandwidth (125 MB/s) to meet the demands of high-luminosity experiments?
  • RQ2Does the integration of a data compression CPU on a PMC card enable effective on-board data reduction without compromising throughput?
  • RQ3Can the platform maintain stable operation over extended periods and under varying thermal conditions?
  • RQ4Is the use of commercial PCI and PMC standards viable for long-term system longevity in high-energy physics experiments?
  • RQ5Can the system reliably handle data integrity and event synchronization across multiple front-end modules?

Key findings

  • The DAQ platform achieved a peak data transfer speed of 125 MB/s using DMA, representing 94% of the theoretical PCI-32 performance.
  • No data errors were detected during 48 hours of continuous operation at room temperature or 77 hours of thermal cycling from 10°C to 50°C.
  • The data reduction software, tested with Monte Carlo-generated signals, achieved a processing speed of 94 MB/s at 20% detector occupancy, sufficient for the required 32 MB/s at 10 kHz trigger rate.
  • The platform demonstrated robustness and stability under extended operation and thermal stress, confirming suitability for long-term deployment.
  • The use of a standard PCI bus and PMC architecture ensures compatibility with current and future commercial components, supporting system longevity.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.