[Paper Review] Development of MicroMegas for a Digital Hadronic Calorimeter
This paper presents the development and beam test validation of MicroMegas detectors with analog and digital readout for use in a Digital Hadronic Calorimeter (DHCAL) at future particle physics experiments. Using bulk PCB technology and embedded ASICs (HARDROC and DIRAC), the prototypes achieve high MIP efficiency (up to 97.05%), low multiplicity (<1.1), and excellent energy resolution (FWHM 19.6%), demonstrating strong suitability for high-granularity, radiation-hard calorimetry in the International Linear Collider context.
Recent developments on the MicroMegas prototypes built by use of the bulk technology with analog and digital readout electronics are presented. The main test beam results of a stack of several MicroMegas prototypes fully comply with the needs of a hadronic calorimeter for future particle physics experiments. A technical solution for a large scale prototype is also introduced.
Motivation & Objective
- To develop a highly granular, radiation-hard, and cost-effective active detector for a Digital Hadronic Calorimeter (DHCAL) in future particle physics experiments.
- To evaluate the performance of MicroMegas prototypes with analog and digital readout under high-energy particle beams, particularly for use in the Particle Flow Algorithm (PFA).
- To demonstrate the feasibility of large-scale MicroMegas production using bulk PCB technology with embedded digital electronics for DHCAL applications.
- To validate the performance of digital readout ASICs (HARDROC and DIRAC) in real beam conditions for future DHCAL prototypes.
Proposed method
- Fabrication of MicroMegas detectors using bulk PCB technology with a 20 µm woven mesh, 3 mm drift gap, and 128 µm amplification gap.
- Implementation of analog readout via 16-channel GASSIPLEX chips and 12-bit VME ADCs for high-resolution charge measurement (0.4 fC/ADC count).
- Integration of two mixed-signal ASICs—HARDROC (baseline) and DIRAC (R&D)—for embedded digital readout with 1-bit or 2-bit resolution.
- Use of 55Fe X-ray source to calibrate gain and energy resolution, measuring FWHM and pressure dependence.
- Beam testing at CERN's H2 SPS line (200 GeV muons/pions) and T9 PS line (7 GeV pions) to assess efficiency, multiplicity, and energy deposition uniformity.
- Construction of a 1 m² prototype using six Active Sensor Units (ASUs), each with 24 ASICs, and 2 mm stainless steel plates for mechanical stability and radiation tolerance.
Experimental results
Research questions
- RQ1Can MicroMegas detectors with embedded digital readout achieve the required MIP efficiency and low multiplicity for a DHCAL in high-rate, high-irradiation environments?
- RQ2How does the performance of analog versus digital readout compare in terms of energy resolution, noise, and uniformity across pads?
- RQ3To what extent does the digital ASIC (HARDROC and DIRAC) functionality hold up under beam exposure, particularly in multi-chamber stacks?
- RQ4What is the achievable energy resolution and gain uniformity of MicroMegas prototypes when exposed to 55Fe X-rays and high-energy pions?
- RQ5Can a large-scale 1 m² MicroMegas prototype be reliably manufactured and tested with full compatibility to the CALICE data acquisition system?
Key findings
- The analog-readout MicroMegas prototypes achieved a measured energy resolution of 8.5% (FWHM 19.6%) with a gain of up to 10,000, confirming high-resolution charge measurement capability.
- The most probable value (MPV) of deposited energy per pad was consistently around 45 fC across all chambers, with a relative dispersion of 11% RMS, indicating excellent uniformity.
- The average electronic noise was only 0.6 fC, demonstrating low pedestal noise and high signal-to-noise performance.
- MIP detection efficiency ranged from 92.99% ± 0.10% (oldest prototype) to 97.05% ± 0.07% (newest), showing significant improvement with manufacturing refinement.
- Hit multiplicity was consistently below 1.1 across all four analog-readout prototypes, confirming low hit multiplicity due to fast signal collection and minimal cross-talk.
- The first prototype with DIRAC ASIC digital readout successfully functioned in beam scanning, though full stack testing is required to fully assess threshold dependence and efficiency.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.